EasyManua.ls Logo

Apollo 3300 IB 1978 - Page 21

Default Icon
134 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
eighteen
6. If gas or vapor
source cannot be
located, contact
a service
center for a
leak
check
before using LP Gas
System.
Electrical
Specifications:
Power requirements: 12
Volts DC 0.6
Amps
Operating
Voltage
Range: l0 to 15
Volts DC
Sensitivity:
Less than 25% of the
L.E.L. (Lower Explosive Level) of Butane
or Pro-
pane gas in air.
Less than 15% of the L.E.L.
of Gasoline vapor in air.
Less than 2% of the L.E.L.
of Ethyl Alcohol vapor in air.
Calibration:
Calibrated
to alarm at
20%
of the L.E.L.
of Propane using a certified
gas mix-
ture
of Propane and
dry air at room temperature
(25+5°C).