15
(6) ACA : Auto-ranging
Range Resolution Accuracy
Frequency
Response
Overload
Protection
0 ~ 4.00A 10mA
±(1.0% rdg + 5 dgt)
50Hz ~ 60Hz
400A r.m.s.
4.00A ~ 40.00A 10mA
±(1.0% rdg + 3 dgt)
40.0A ~ 200.0A 100mA
200.0A ~ 300.0A 100mA
±(3.0% rdg + 3 dgt)
0 ~ 4.00A
10mA
±(2.0% rdg + 7 dgt)
40Hz ~ 1KHz
4.00A ~ 40.00A
40.0A ~ 200.0A 100mA
200.0A ~ 300.0A 100mA
±(5.0% rdg + 5 dgt)
±(2.0% rdg + 5 dgt)