Type | Digital Multimeter |
---|---|
Counts | 6000 |
Max DC Voltage | 1000 V |
Max AC Voltage | 750 V |
Max DC Current | 10 A |
Max AC Current | 10 A |
Max Resistance Measurement | 60 MΩ |
Data Hold | Yes |
Backlight | Yes |
Continuity Test | Yes |
Diode Test | Yes |
Power Supply | 9V battery |
Display | LCD |
Temperature Range | -20°C ~ 1000°C |
Safety Category | CAT IV 600 V |
Lists items included with the Digital Multimeter.
Explains terms and symbols related to meter safety.
Describes the LCD display features and indicators.
Explains its function for selecting measurement modes.
Identifies the common ground input connector.
Identifies the positive input for Volts, Ohms, Frequency.
Identifies the positive input for Amp measurements up to 340mA.
Identifies the positive input for Amp measurements up to 10A.
Explains manual ranging and range selection.
Describes its use for AC/DC and Resistance modes.
Explains its function to freeze the displayed reading.
Describes its use for frequency display during AC measurements.
Details display, polarity, overrange, low battery, sampling, and operating conditions.
Provides physical dimensions and included accessories.
Details ranges, resolution, accuracy, and protection for DC Voltage.
Details ranges, resolution, accuracy, and protection for AC Voltage.
Details ranges, resolution, accuracy, and voltage burden for DC Current.
Details ranges, resolution, accuracy, and voltage burden for AC Current.
Details ranges, resolution, accuracy, and overload protection for Resistance.
Details range, accuracy, test current for diode/continuity.
Details ranges, resolution, sensitivity, accuracy for Freq/RPM.
Explains Auto Power Off and Hz sensitivity features.
Provides pre-measurement steps and safety warnings.
Details connecting leads and setting the meter for voltage.
Details connecting leads and setting the meter for current.
Details connecting leads and setting the meter for resistance.
Explains how to perform a continuity check.
Details how to perform a diode check and interpret results.
Explains how to measure frequency and RPM.
Provides general cleaning and servicing instructions.
Step-by-step guide for installing or replacing batteries.
Details how to examine or replace the meter's fuse.
Describes using the probe holder for operation and storage.
Explains using the stand for reading and holster for hanging.