Owner’s manual for installation,
use and maintenance
This manual is property of the owner. Leave with the unit when set-up and start-up are complete.
AQC Dust Collecng Systems inc. reserves the right to change design and specicaons without prior noce.
2MCH2-8, 2MCH3-12, 2MCH4-16, 3MCH2-12, 3MCH3-18, 3MCH4-24, 4MCH2-16, 4MCH3-24,
4MCH4-36, 5MCH4-40, 6MCH4-48, 7MCH4-56, 8MCH4-64, 9MCH4-72, 10MCH4-80

Questions and Answers

  • P
    Pamela MorganAug 6, 2025
    Why is there insufficient suction of smoke, vapor, or dust in my AQC Industrial Equipment?
    • K
      Kenneth MorenoAug 6, 2025
      If your AQC Industrial Equipment isn't sucking up smoke, vapor, or dust effectively, several factors could be at play. First, verify that the fan is rotating in the correct direction. Next, ensure all access doors are properly sealed, checking the gaskets and hopper for any leaks. Obstructions at the fan outlet can also reduce suction, so remove any debris and adjust the air damper. Insufficient pressure in the air system could be the cause, so ensure there is a minimal 90 psig in the system. Leaks in the compressed air system can also lead to insufficient suction. Check for debris, wear and tear, or breaks in the diaphragm valve, and inspect solenoids near the pneumatic hoses for leaks, replacing if necessary.
  • S
    stanleywalkerAug 18, 2025
    How to fix dust or smoke coming from the clean air outlet of my AQC Industrial Equipment?
    • S
      smithvictoriaAug 18, 2025
      If you notice dust or smoke at the clean air outlet of your AQC Industrial Equipment, it could be due to several reasons. The cartridges might not be installed correctly, so check their installation and repair if necessary, ensuring the whole assembly is sealed. Also, the cartridges may not be adjusted properly; screw them in tight to ensure the gaskets are squeezed against the frame. Damaged cartridges can also cause this issue, so replace any defective filters. Finally, check the gaskets on the access doors, honeycomb plate, and filters for any damage.
  • L
    leonardrodriguezAug 25, 2025
    What does it mean when the alarm light is ON in my AQC Industrial Equipment (DCT-1000)?
    • K
      Kathryn MitchellAug 25, 2025
      If the alarm light is on for your AQC Industrial Equipment (DCT-1000 model), it could be due to several reasons. The alarm value might be set too low, so try adjusting it to a higher value. Alternatively, there might be too much pressure loss, so check and clean the compressed air system, and replace the cartridges if normal pressure does not resume. Another potential cause is a pneumatic data hose that is unplugged, broken, or clogged, so inspect the hoses connected to the DCP pressure module for any leaks or tears, and replace if necessary.
  • D
    Dr. Bryan HunterAug 29, 2025
    Why is the cleaning cycle light ON but nothing happens on my AQC Industrial Equipment?
    • R
      Robin RamirezAug 30, 2025
      If the cleaning cycle light is on but nothing happens with your AQC Industrial Equipment, first check the wiring between the sequencer card and solenoids. If the wiring is correct, the solenoids themselves might be defective, so check if they are working properly. Finally, the sequencer card could be defective, so check it following the manufacturer’s recommendations.
  • L
    Lauren RobinsonNov 10, 2025
    What to do if my AQC Industrial Equipment has insufficient suction of dust?
    • S
      Sean AlvaradoNov 10, 2025
      If you're experiencing insufficient dust suction with your AQC Industrial Equipment, several issues could be the cause. The sequencer card might not be responding, so check if the voltage output to the card is sufficient and replace the fuse if needed. Insufficient air pulse cleaning can also lead to this problem, so verify the voltage output to the card and replace the fuse if necessary. Ensure there is a minimal 90 psig in the system to avoid shortage of compressed air. Valves not working properly can also reduce suction; inspect the diaphragm valve for debris, wear, or breaks, and check for leaks at the solenoids and on the pneumatic hoses. Also, verify that the cleaning delay and duration are adequate. High humidity levels can load the filters, so check for relative humidity and leaks,...

Summary

Introduction

Information on the Dust Collector

Presentation

Each MAXIFLO unit includes

Lists components and features included with each unit.

Normal Use

Operation

Cartridge cleaning

Explains the reverse air pulse technology for cleaning cartridges.

Installation

Inspection of goods

Procedures for inspecting the unit upon receiving it for damage.

Location

Guidelines for selecting an appropriate installation location for the dust collector.

Assembly

Required tools

Lists necessary tools and equipment for assembling the dust collector.

Assembly

Structure Assembly

Electrical Connection

Electrical connection for DCT-500 sequencer

Details wiring and connection for the DCT-500 sequencer.

DCT-500 board specifications

Lists technical specifications for the DCT-500 sequencer board.

Electrical connection for DCT-1000 sequencer

DCT-1000 board specifications

Lists technical specifications for the DCT-1000 sequencer and DCP module.

Compressed air connection

Ventilation ducting

Start Up

Check list

Pre-startup checklist to ensure proper continuous operation.

Electrical Connections

Check list

Pre-startup checklist for electrical connections.

Electrical connections

General guidance and safety for making electrical connections.

Optional equipment

Details on optional equipment like quick clip drum, ramp, and buggy.

Anti-abrasive inlet

Describes the anti-abrasive inlet option for filtering abrasive particles.

Platform and ladder

Information on available platforms and ladders for unit access.

Explosion relief vent

Guidelines and specifications for explosion relief vent systems.

Magnehelic Gauge

Start;Stop Procedure

Start up with new filters

Procedure for initial startup with new filter cartridges.

Regular start up

Steps for routine startup of the dust collection system.

Shut down

Safe procedures for shutting down the dust collection system.

Safety

Staff-Workers

Safety guidelines for personnel working on or around the dust collector.

Electrical components

Safety precautions for handling electrical components.

Explosive dusts

Safety considerations when dealing with explosive or flammable dusts.

Anchors

Requirements for anchoring the unit for stability and safety.

Interior installation

Safety guidelines for indoor installation, especially with explosion vents.

Spark producing activities

Safety precautions regarding activities that produce sparks near the unit.

Maintenance

Remplacement of cartridges

Information on the lifespan and replacement of filter cartridges.

Remplacement of cartridges

Detailed steps for safely removing and replacing filter cartridges.

Compressed Air System

Explosion vent

Checklist for inspecting explosion vents for proper function and safety.

Control panel

Explanation of the control panel and sequencer functions.

Programming Instructions

DCT-500 sequencer

Instructions for programming the DCT-500 sequencer settings.

DCT-1000 sequencer

Details on programming parameters for the DCT-1000 sequencer.

Maintenance and Inspection

Troubleshooting

Warranty

Limitation of Liability

Applicability

Governing Law

AQC Maxiflo 2MCH2-8 Specifications

General IconGeneral
BrandAQC
ModelMaxiflo 2MCH2-8
CategoryIndustrial Equipment
LanguageEnglish