These settings are also for the replacement of the vintage Signature 2012
and earlier ( Part # 17P549-03 ) with the 2013 ( 100-202A ) control board
Setting up the unit So the Display shows the Water Temp. in Fahrenheit instead of Celsius
1. Hold down the “Up” and “Down” arrows for approximately 10 seconds
2. Unit will display “ F – C “ , this is the calibration for Fahrenheit or Celsius
3. Press the “Up” Arrow to Select “ *F “
4. Once the selection is made wait 10 seconds for the display to time out and go back to the normal
display. The unit should now display the water Temp. in Fahrenheit.
Setting up the Unit for cooling function on A Heat / Cool Model
1. Hold down the “Up” and “Down” arrows for approximately 10 seconds
2. Unit will display “ F – C “ , this is the calibration for Fahrenheit or Celsius
3. Press the “Hand” button until it reads the “ P - C “ on the display
4. Press the “Up” arrow twice so that the Display reads “ EnA
5. Once the selection is made wait 10 seconds for the display to time out and go back to the normal
display. Now press the “ Hand “ button until you the display reads “PHC “.
6. Press the “ Up” or “Down” arrow to select either “P_H” for heating or “P_C” for cooling.
Setting the Filter timer function to Disabled on the Heatpump
1. It is important that the “ FiL” setting is set to “DIS” for disabled. If the “FiL” setting is enabled follow
these steps
2. Hold down the “Up” and “Down” arrows for approximately 10 seconds
3. Unit will display “ F – C “ , this is the calibration for Fahrenheit or Celsius
4. Press the “Hand” button until it reads the “ FiL”
5. Press the “Down” arrow until it reads “DIS”
6. Once the selection is made wait 10 seconds for the display to time out and go back to the normal
display.
Calibrations and Settings for ACT
Signature Series and XL Series
Manufactured from 2013 through 2-26-15
with Serial number 1500379 and lower
Models :
ACT750,
ACT1100,
ACT1250,
ACT1500,
ACT1750,
And All H/C Variants
THE POOL HEATING SOLUTION
Question and Answer IconNeed help?

Do you have a question about the Aqua Comfort ACT1100 and is the answer not in the manual?

Aqua Comfort ACT1100 Specifications

General IconGeneral
ModelACT1100
Heating Capacity11 kW
RefrigerantR410A
TypeAir to Water Heat Pump
Power Supply220-240V, 50Hz

Summary

Heat Pump Control Panel Settings

Set Fahrenheit Display

Configure the unit to display water temperature in Fahrenheit instead of Celsius.

Set Cooling Function

Enable or disable the cooling function on Heat/Cool models via the control board.

Disable Filter Timer

Set the filter timer function to 'DIS' (disabled) on the heat pump control panel.

Heat Pump Calibration Procedures

Calibrate Water Temperature

Adjust the displayed water temperature to match the actual water temperature.

Adjust Deadband Setting

Modify the temperature deadband, which controls how long the unit stays off.

Defrost Mode Selection

Select between air defrost ('Alr') or reversing valve defrost ('rEC').

Bypass 5-Minute Delay

Disable the heat pump's 5-minute start-up delay to allow immediate operation.