EasyManua.ls Logo

Aqua One 104F - Maintenance 101;102 F

Aqua One 104F
12 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6
GB
Maintenance 101/102F
1. Unplug from the power supply. Take to sink.
2. Remove the sponge casing from motor to access the
lter sponge. (102F has 2)
3. Remove sponge and squeeze gently a few times in
a bucket of aquarium water. It is important to not wash
the sponge too thoroughly and never wash it in tap
water.
If you have a 102F only wash one sponge at a time
and rotate them. This will help keep your lter working
better.
Accessing The Impeller
Clean the impeller at least once a month.
1. Grasp the motor with one hand and lter casing with
the other and gently pull apart.
2. Remove the impeller cover to gain access to the
impeller.
3. Pull impeller from the motor and rinse properly. Use
an Aqua One double ended pipe brush to clean the
impeller and the impeller well and also any of the outlet
options that are being used.
4. Put the lter back together and return to the aquarium.
Ensure your hand is not wet, plug in at the power supply
and turn on.

Related product manuals