Aqua Systems Eradicator II AIF - User Manual

Aqua Systems Eradicator II AIF
40 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© 2014 New Aqua LLC dba Aqua Systems 7785 East US Hwy 36 Avon, IN 46123
1
Eradicator II AIF Systems
Installation, Operation,and
Maintenance Manual
Eradicator II AIF
Air Induction Filter Systems
Installation, Operation,
and Maintenance Manual
114 Vista Parkway
Avon, IN 46123
(317) 272-6721 • (800) 272-5511
© 2014 New Aqua LLC
Patent # 7,300,569
>
>

Questions and Answers

  • S
    Stacy SmithAug 9, 2025
    Why does Aqua Systems Water Filtration Systems control valve regenerates at wrong time?
    • S
      Steven NixonAug 9, 2025
      If your Aqua Systems Water Filtration System control valve regenerates at the wrong time, this could be due to a few reasons. Power outages can cause this, so reset the control valve to the correct time of day. Make sure the time of day is set correctly. Also, check that the regeneration time is set correctly. Verify the control valve is not set at 'on 0' (immediate regeneration) by checking the control valve set-up procedure regeneration time option. Also check if the control valve is not set at NORMAL + on 0, using the same procedure.
  • C
    Craig McintoshAug 15, 2025
    Why Aqua Systems Water Filtration Systems timer does not display correct time of day?
    • L
      leon27Aug 15, 2025
      If the timer on your Aqua Systems Water Filtration System does not display the correct time of day, it might be due to a switched outlet; use an uninterrupted outlet. A power outage could also be the reason; in this case, reset the time of day. If neither of these solutions work, the PC board might be defective, requiring a replacement.
  • A
    April ClayAug 20, 2025
    What to do if Aqua Systems Eradicator II AIF Water Filtration Systems shows no softening or filtering when water is flowing?
    • P
      Patrick WalkerAug 20, 2025
      If your Aqua Systems Water Filtration System isn't showing softening or filtering when water is flowing, first, ensure the bypass valve is in the service position, not the bypass position. Check if the meter connection is disconnected and connect the meter to the PC board. Inspect the meter turbine for restrictions or stalling, removing the meter to check for rotation or any foreign material. If the meter is defective, it should be replaced. Finally, a defective PC board could also be the cause, requiring replacement.
  • D
    Darin SantiagoAug 27, 2025
    How to fix Aqua Systems Eradicator II AIF timer when it does not display time of day?
    • J
      juandeckerAug 27, 2025
      If the timer on your Aqua Systems Water Filtration System isn't showing the time of day, check if the transformer is unplugged and connect the power. Ensure there is electric power at the outlet; repair the outlet or use a working one. If these steps don't resolve the issue, the transformer or PC board may be defective, requiring replacement.
  • C
    Chad SimmonsNov 2, 2025
    What to do if Aqua Systems Eradicator II AIF shows a system error?
    • D
      Daniel EvansNov 2, 2025
      If your Aqua Systems Water Filtration System displays 'ERROR' on a red screen, it could be due to several reasons. First, if the control valve was recently serviced, try pressing NEXT and REGEN for 3 seconds, or unplug the power source (black wire) and plug it back in to reset the control valve. Another cause might be foreign matter lodged in the control valve; inspect the piston and spacer stack assembly. High drive forces on the piston can also trigger this error, requiring replacement of the piston(s) and spacer stack assembly. Ensure the control valve piston is in the home position by performing the reset procedure. Check the motor and its wiring, replacing the motor if needed. Inspect the drive gear for dirt, damage, or missing labels, replacing or cleaning as necessary. Verify that t...

Summary

Introductory Information

Owner Information Fields

Fields for owner and installation details for system record-keeping.

Welcome and System Overview

Introduces the Eradicator II AIF system and its benefits for water treatment.

System Operation Explained

Treatment Cycle Description

Explains the normal water flow and air interaction during the treatment cycle.

Regeneration Cycle Process

Details the steps involved in the regeneration process to clean the media.

Air Induction Mechanism

Describes how air is introduced into the system via the venturi.

System Limitations and Notes

Covers pH requirements, flow, effervescence, and chemical restrictions.

Pre-Installation Procedures

Operational Specifications

Lists critical water pressure, flow rate, temperature, and drain requirements.

Installation Site Data Fields

Sections for recording bypassed lines and sizing information.

Important Pre-Install Tips

Advice on pH, freezing, placement, outside faucets, and sand.

Bypass Valve Functions

Normal Operation Mode

How the valve directs water for standard system use.

Bypass Mode Function

Isolates the control valve for maintenance while supplying untreated water.

Diagnostic Mode Use

Allows service on a pressurized system while bypassing the control valve.

Shut Off Mode Purpose

Stops all water flow to the plumbing system for isolation.

System Installation Guide

Unit Placement Guidelines

Criteria for selecting the optimal location for the AIF system.

Plumbing and Connections

Instructions for pipe connections, sealants, and avoiding damage.

Water Line Hookup

Details on connecting inlet, outlet lines, and the drain connection.

Initial Water Turn-On

Steps for pressurizing the system and performing leak checks.

Initial Unit Start-Up

Powering Up the Unit

Initial steps for plugging in the unit and setting the clock.

System Filling and Testing

Guides on filling the tank, checking the drain line, and starting the first cycle.

Air Effervescence Note

Explains temporary milky water appearance due to residual air.

Control Unit Programming

Setting the Current Time

Instructions for configuring the system's internal clock.

Installer Configuration Options

Covers regeneration timing, day override, and energy saver modes.

Regeneration Cycle Control

Details automatic regeneration and manual initiation methods.

Control Valve Servicing

Removing the Control Valve

Step-by-step guide for detaching the control valve from the media tank.

Reinstalling the Control Valve

Procedures for correctly reattaching a new or serviced control valve.

Component Parts Identification

Quick Connect Assembly Parts

Illustrated parts list for the quick connect assembly.

Drive System Components

Diagrams and part numbers for motor, PC board, and gears.

Piston and Spacer Stack Parts

Illustrated parts for piston and spacer stack assemblies.

Injector Assembly Parts

Diagrams and part numbers for injector cap, screen, and various injectors.

Air Injection Port Components

Illustrated parts list for the air injection port.

Drain Assembly Parts

Diagrams and part numbers for the drain assembly and flow controls.

Meter Assembly Parts

Illustrated parts list for the water meter assembly.

Elbow Assembly Parts

Diagrams for NPT and Solvent elbow assemblies.

Bypass Valve Components

Illustrated parts list for the bypass valve.

Service Tools

Shows the specialized valve wrench for servicing.

Detailed Maintenance Guide

Drive Assembly Servicing

Detailed instructions for servicing the drive assembly and gears.

Piston and Drive Cap Maintenance

Procedures for removing, cleaning, and replacing pistons and drive caps.

Spacer Stack Assembly Care

Guidance on handling and cleaning the spacer stack assembly.

Injector and Refill Flow Control Service

Steps for servicing injector components and refill flow control.

Water Meter Servicing

Instructions for servicing the water meter or meter plug.

Bypass Valve Maintenance

Guidance on disassembling and reassembling the bypass valve.

Problem Solving and Diagnostics

Timer and Display Problems

Solutions for timer not displaying or showing incorrect time.

Softening;Filtering Functionality Issues

Troubleshooting steps for when the system isn't softening or filtering.

Regeneration Cycle Malfunctions

Addresses issues with regeneration timing and automatic operation.

System Error Screen Resolution

Explains how to interpret and fix error messages shown on the display.

Additional Troubleshooting Notes

Discusses regeneration time, water usage during regen, and system capacity limits.

Aqua Systems Eradicator II AIF Specifications

General IconGeneral
BrandAqua Systems
ModelEradicator II AIF
CategoryWater Filtration Systems
LanguageEnglish