Type of motor enclosure
Thermal class
Motor speed approx. (rpm)
Max. continuous sound
intensity level dB (A)
Max. water temperature (°C)
Max. casing interior pressure (bar)
IP X4
B
2840
£ 70
1)
60
2,5
For standard voltage according to IEC 38
and DIN EN 60034 (Euro-voltage).
Suitable for continuous operation 1~ 220 - 240 V.
Tolerances ± 5%.
1)
Measured with phonometer according to DIN 45635.
8. Technical Data
Subject to technical modifications!
Technical data at 50 Hz
Inlet / outlet d (mm)
Rec. inlet / outlet pipe, PVC-pipe, d
Power input P
1
(kW) 1~ 230 V
Power output P
2
(kW) 1~ 230 V
Rated current (A) 1~ 230 V
Weight (kg)
Aqua Plus 4
50 / 50
50 / 40
0,36
0,18
1,95
6,30
Aqua Plus 6
50 / 50
50 / 40
0,45
0,25
2,30
6,60
Aqua Plus 8
50 / 50
50 / 50
0,60
0,40
2,70
7,50
Aqua Plus 11
50 / 50
50 / 50
0,69
0,45
3,20
7,60
12
AQUA Plus
L
4
6
8
11
511
511
496
496
AQUA Plus 4
AQUA Plus 11
AQUA Plus 8
AQUA Plus 6
n = 2840min
-1
In
Out
257
178
335
345
L
8
93
296
8
10
130
160
200
225
~
210
Min. space for servicing
298
337
4
0
2
20
Q (m³/h)
10515253040
H (m)
6
8
10
12
14
16
18
20
Flow rate
Total head
Glue socket d=50
2
1
4
Hose adapter 1 / " or 1 / " hose
1