This manual covers the preliminary installation, operation and general
maintenance requirements for Aquafine Ultraviolet Water Treatment
Equipment for the following applications:
• Disinfection
• Ozone
• TOC Reduction
• Chlorine/Chloramine Destruction
It is imperative that those responsible for the installation of this equipment,
as well as operating personnel, read this manual and carefully follow all
instructions and guidelines.
EQEQ
EQEQ
EQ
UIPMENT OPERAUIPMENT OPERA
UIPMENT OPERAUIPMENT OPERA
UIPMENT OPERA
TT
TT
T
ORS ORS
ORS ORS
ORS
AND INSTAND INST
AND INSTAND INST
AND INST
ALLERSALLERS
ALLERSALLERS
ALLERS
MUST COMPLMUST COMPL
MUST COMPLMUST COMPL
MUST COMPL
Y Y
Y Y
Y
WITH OPERAWITH OPERA
WITH OPERAWITH OPERA
WITH OPERA
TIONTION
TIONTION
TION
AL SAFETY REQAL SAFETY REQ
AL SAFETY REQAL SAFETY REQ
AL SAFETY REQ
UIREMENTSUIREMENTS
UIREMENTSUIREMENTS
UIREMENTS
..
..
.
Aquafine Corporation builds the finest quality ultraviolet equipment in the
world. When properly installed and operated, Aquafine ultraviolet
treatment units will provide many years of service.
Installation,
Maintenance and
Operation Manual
RBE Series
READ THIS MANUAL
PLEASE KEEP FOR PERMANENT REFERENCE
Part No. 115-2, Revised 6/01, v. 1.1

Questions and Answers

  • J
    James PenaAug 9, 2025
    Why is the quartz sleeve in my Aquafine Water Filtration System dirty after 30 days?
    • V
      Vickie GarciaAug 9, 2025
      The quartz sleeve in your Aquafine Water Filtration System might be dirty after thirty days of use due to minerals, debris, and other substances present in the water. To resolve this, wash the quartz sleeves with mild soap and water, then rinse them with clean, hot water.
  • S
    Shelly HamiltonAug 14, 2025
    Why is the UV lamp failing so quickly in my Aquafine Water Filtration System?
    • F
      fwilliamsAug 15, 2025
      Premature lamp failure or lamp life deterioration in your Aquafine Water Filtration System can occur if the UV unit is cycled on and off more than three times a day. To prevent this, limit the UV unit cycling to no more than three times daily.
  • M
    Mark ChangAug 20, 2025
    What to do if the voltage reading is zero in Aquafine RBE-24R/60 Water Filtration Systems?
    • M
      melanie96Aug 20, 2025
      If the voltage reading is zero or a number above or below the acceptable ranges in your Aquafine Water Filtration System, it indicates a ballast fault. Replace the ballast connected to the 'faulty' UV lamp to resolve this issue.
  • J
    James PerezAug 27, 2025
    How to fix the LED bulb if it doesn't light after replacing the UV lamp in Aquafine RBE-24R/60?
    • D
      Danny PatelAug 27, 2025
      To troubleshoot why the LED bulb does not light after replacing the UV lamp in your Aquafine Water Filtration System, verify the electrical output of the ballast connected to that specific UV lamp by testing the ballast open circuit voltage.
  • D
    Deanna CoxSep 1, 2025
    What to do if the LED doesn't light but voltage is ok in Aquafine Water Filtration Systems?
    • T
      Theresa BlackSep 1, 2025
      If the voltage reading is within acceptable ranges but the LED does not light in your Aquafine Water Filtration System, the LED board has likely failed. Replace the LED board to fix this.

Summary

Installation and Operational Safety

Safety Requirements for UV Equipment

Highlights mandatory safety requirements for operator protection and equipment integrity.

Warranty Information

Conditions Voiding Equipment Warranty

Lists actions or failures that will invalidate the product warranty.

Unit Installation Procedures

Unit Installation and Wiring

Electrical Wiring and Grounding

Details on connecting electrical power and the importance of proper grounding.

Installing the Quartz Sleeves

New Equipment Installation

Step-by-step guide for installing new quartz sleeves in the UV unit.

Quartz Sleeve Replacement

Installing the Ultraviolet (UV) Lamps

Single-Ended Lamp Design (Post-1999)

Guide for installing single-ended lamps in units manufactured after January 1, 1999.

UV Lamp Installation for Double-Ended Units

Double-Ended Lamp Design (Pre-1999)

Instructions for installing double-ended lamps in older units.

UV Lamp Installation for High-Temperature Units

High-Temperature (HT) Unit Procedures

Specific steps for installing UV lamps in high-temperature units.

UV Lamp Installation for USD-RBE Series Units

Powering Up the Ultraviolet (UV) Unit

Pre-Operation Checks and Startup

Verifies connections and performs initial power-up sequence for the UV unit.

UV Monitoring Sensors and Alarms

Troubleshooting UV System Issues

Diagnosing Ballast and LED Display Problems

Guide for troubleshooting lamp issues by testing ballast open circuit voltage.

Performance Verification and Sampling

Ballast Replacement Procedure

Steps for Ballast Replacement

A step-by-step guide for replacing a faulty ballast in the UV unit.

Aquafine RBE-24R/60 Specifications

General IconGeneral
ModelRBE-24R/60
CategoryWater Filtration Systems
ManufacturerAquafine
Flow Rate60 GPM
Flow Rate (GPM)60
Voltage120-240V