EasyManua.ls Logo

AQUATRIP AT302 - User Manual

AQUATRIP AT302
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Pg. 1
Model AT302
Installaon and Owners Manual
The installing Plumber and the User MUST read this manual before use, to ensure
they understand the installation, operation, and service requirements of the system.
SECTION PAGE
1. Introducon and how it works…………………………………………………………………………………………….. 2
2. Installaon Preparaon and Warning Precauons ................................................................... 3
3. Commissioning the Control Panel and Control Box before installaon .................................... 4
4. Shuto Valve installaon .......................................................................................................... 5
5. Flow Sensor explanaon and installaon ................................................................................. 6
6. Mounng the Control Box ........................................................................................................ 6
7. The System Check procedure .................................................................................................... 8
8. Control Panel radio range tesng and set up procedures ........................................................ 9
9. The Radio Communicaons System - Operaon and Troubleshoong ..................................... 10
10. Emergency Manual Override and Fire ghng procedure ....................................................... 11
11. The Control Panel Reference Guide .......................................................................................... 11
a. The RESET WATER buon ................................................................................................... 12
b. The INFO buon .................................................................................................................. 13
Informaon Messages ..................................................................................................... 13
System Warning Messages .............................................................................................. 14
c. The OK MENU buon .......................................................................................................... 15
Set Up Menu summary .................................................................................................... 15
Flow Time sengs ........................................................................................................... 16
Peak Flow Periods ............................................................................................................ 17
Exclusion Period (Sleep Mode) ........................................................................................ 17
Turn Water O command ................................................................................................ 18
The Clock .......................................................................................................................... 18
The Trip Counter .............................................................................................................. 18
Nite Watch seng ........................................................................................................... 18
Away Watch seng ......................................................................................................... 19
Wetness Sensor set up .................................................................................................... 19
Radio Range Test ............................................................................................................. 20
d. The OVERRIDE buon ......................................................................................................... 20
e. The HOME AWAY buon .................................................................................................... 21
12. How to test and change the baeries ...................................................................................... 21
13. System Use and Funcon Warnings ......................................................................................... 23
14. System Troubleshoong and Leak Diagnoscs .......................................................................... 24
15. System Service and Maintenance Requirements ..................................................................... 25
16. Water Meter connecon and other oponal accessory funcons ........................................... 25
17. Technical Specicaons ............................................................................................................. 26
18. Cercaons and Regulatory ................................................................................................... 26
19. Service Records ......................................................................................................................... 27
20. Customer Handover and Installaon checklist ......................................................................... 28
21. Warranty Policy ......................................................................................................................... 28
Table of Contents
Question and Answer IconNeed help?

Do you have a question about the AQUATRIP AT302 and is the answer not in the manual?

Summary

Introduction and How It Works

Installation Preparation and Warning Precautions

Commissioning the System

Special Note for Pressure Pump Water Supplies

Details specific setup for properties with pressure pump water supplies.

Shutoff Valve Installation

Horizontal Pipe Installations

Guide for installing the shutoff valve in a horizontal pipe configuration.

Vertical Pipe Installations

Guide for installing the shutoff valve in a vertical pipe configuration.

The Flow Sensor

Horizontal Installation

Instructions for mounting the flow sensor in a horizontal pipe.

Vertical Installation

Instructions for mounting the flow sensor in a vertical pipe.

Mounting the Control Box

Above Ground Installation Options

Options for mounting the control box above ground for optimal radio range.

Below Ground Installation Options

Options for mounting the control box below ground.

System Check Procedure

Control Panel Radio Range Testing

Testing the Radio Range of the Control Panel

Procedure to test radio signal strength between Control Panel and Control Box.

Radio Signal Delay

Explains signal delay for battery life and update intervals.

Radio Signal Strength Contributing Factors

Factors affecting radio signal strength and potential solutions.

Radio Communications System Operation and Troubleshooting

Manual Radio Link Procedure

Steps to manually establish a radio link between devices.

Automatic Radio Link Procedure Option

How the system automatically links after a period of inactivity.

Emergency Manual Override and Fire Fighting Procedure

The Control Panel

11.a The RESET WATER button

Explains how to use the RESET WATER button to turn water back on.

11.b The INFO button

Explains how the INFO button displays system status and warning messages.

11.c The OK MENU button

Details how to access setup menus and adjust system settings using the OK MENU button.

11.d The OVERRIDE button

How to temporarily disable leak detection for a set period.

11.e The HOME AWAY button

How to switch between HOME and AWAY modes for different water usage scenarios.

RADIO RANGE TEST

How to Test and Change Batteries

Control Box Battery Replacement

Step-by-step guide to replacing batteries in the Control Box.

Control Panel Battery Replacement

Step-by-step guide to replacing batteries in the Control Panel.

System Use and Function Warnings

System Troubleshooting and Leak Diagnosis

System Service and Maintenance Requirements

Regular System Testing

Recommends testing the system every six months for proper function.

Certified System Testing

Requirements for professional testing, often for insurance discounts.

Battery Testing

How to check battery levels and when to replace them.

Flow Sensor Servicing

Procedures for servicing or replacing the flow sensor.

Shutoff Valve Servicing

Maintenance requirements for the shutoff valve, including diaphragm replacement.

Debris Filter Servicing

How to clean or replace the debris filter in the flow sensor.

Other Optional Accessories

Slave Control Panel

Describes an optional wireless remote panel for basic control.

Wireless Wetness Sensors

Explains optional sensors that detect water leaks on the floor.

Flow Sensor Extension Cables

Cables to extend the distance between the control box and flow sensor.

Technical Specifications

Certifications and Regulatory

Customer Handover and Installation Checklist

Customer Handover

Steps the plumber must take to hand over the system to the user.

Plumbers Installation Checklist

A checklist for plumbers to confirm user understanding and system setup.

Warranty

AQUATRIP AT302 Specifications

General IconGeneral
BrandAQUATRIP
ModelAT302
CategorySwitch
LanguageEnglish