ARAG bravo 350 Series - User Manual

ARAG bravo 350 Series
50 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
BRAVO 350 SERIES COMPUTER
ORCHARD SPRAYER
DIRECT CONNECTION
Software rel. 1.3.x
INSTALLATION, USE AND MAINTENANCE
467354XXXX
WWW.ROLTRONIK.PL

Table of Contents

Other manuals for ARAG bravo 350 Series

Questions and Answers

  • E
    Eric CuevasSep 15, 2025
    What to do if unable to reach output volume value set for the automatic operation on ARAG Control Systems?
    • R
      Ryan TranSep 15, 2025
      If you are unable to reach the output volume value set for automatic operation, it may be due to a wrong setup, the system not being adequately sized, or a control valve malfunction. Check the setup of the application rate and the row width. Also, check the maximum pressure valve adjustment, ensure the control valve is adequate, and verify the valve operation.
  • J
    Jessica CoffeyAug 25, 2025
    What to do if the instantaneous pressure is not displayed on ARAG Farm Equipment?
    • S
      Stephanie DuarteAug 25, 2025
      If the instantaneous pressure isn't showing on your ARAG Farm Equipment, there could be a few reasons. First, check the setup of the pressure sensor. Secondly, ensure that the computer is receiving signals from the pressure sensor. Finally, verify the connections to the pressure sensor, as incorrect installation might be the cause.
  • H
    hoffmanmichaelAug 26, 2025
    Why is the displayed speed not precise on my ARAG Farm Equipment?
    • R
      ruth77Aug 26, 2025
      An imprecise speed display on your ARAG Farm Equipment is often due to an incorrect wheel constant setup. Check the setup of the wheel constant.
  • I
    iunderwoodAug 26, 2025
    What to do if the display does not switch on ARAG Farm Equipment?
    • M
      Michael KrauseAug 27, 2025
      If the display on your ARAG Farm Equipment doesn't turn on, first, ensure there is a power supply by checking the power supply cable connections. If the power is on, check if the computer is OFF and press the ON key.
  • J
    jacobsbrandonSep 16, 2025
    Why is the displayed tank level not precise on ARAG bravo 350?
    • P
      Patricia HendersonSep 16, 2025
      If the displayed tank level is not precise, it may be due to the level sensor not being calibrated or wrongly installed. Perform the calibration and check the connections to the level sensor.
  • J
    Joanna NelsonSep 23, 2025
    What to do if during the tank calibration procedure, the sprayed quantity is always steady on zero in ARAG bravo 350 Control Systems?
    • J
      Jenna DuffySep 23, 2025
      If, during the tank calibration procedure, the sprayed quantity is always steady on zero, it could be due to wrong installation, no flowmeter installed, or section valves and main control set to OFF. Check connections to the flowmeter, install the flowmeter on the system, and set section valves and main control to ON.
  • S
    Sara ButlerSep 8, 2025
    What to do if the display speed is not precise on ARAG Control Systems?
    • J
      Justin RiversSep 8, 2025
      If the displayed speed is not precise, the setup of the wheel constant may be incorrect. Check the setup of the wheel constant.
  • A
    Andrew BaileySep 9, 2025
    Why is the instantaneous pressure readout inaccurate on ARAG Control Systems?
    • B
      Benjamin SmithSep 9, 2025
      An inaccurate instantaneous pressure readout may be due to an incorrect setup of the full scale for the pressure sensor or a wrong installation of the pressure sensor. It's recommended to check the setup of the full scale for the pressure sensor and the connections to the pressure sensor.
  • S
    Sheila SmithSep 2, 2025
    Why valve controls take no effect on ARAG Farm Equipment?
    • J
      Jesse WiseSep 2, 2025
      If the valve controls on your ARAG Farm Equipment aren't working, it might be because the valves are not connected. Connect the connectors.
  • A
    Ashley FrostAug 31, 2025
    How to calibrate the displayed tank level on ARAG Farm Equipment if it is not precise?
    • L
      Leslie ButlerAug 31, 2025
      If the displayed tank level on your ARAG Farm Equipment is not precise, it might be due to the level sensor. Perform the calibration, and if that doesn't work, calibrate the level sensor again. Also, check the connections to the level sensor, as incorrect installation could be the cause.

Summary

Foreword

Manual Foreword and Use

Provides instructions to assemble, connect, and set BRAVO 350 computers.

Manual Use Modes

Contains technical terms for installers; installation by trained personnel is mandatory.

Installation

Package Content

Lists the items included in the BRAVO 350 direct connection package.

System Recommended Composition

Illustrates the typical system configuration with BRAVO 350 and connected components.

Setting

Tests and Checks Before Setting

Ensures all components are correctly installed and connected before computer configuration.

Computer Switching On;Off

Details the procedures for ordinary switching on and accessing advanced setup.

Advanced Setup

Ultrasonic Configuration

Sets parameters for ultrasonic sensors, including sensors-boom distance.

Sections Configuration

Configures the number of section valves and boom type (single/double).

User Setting

Job Selection

Allows selecting or creating a job for spraying operations.

Current Job Data

Displays real-time data for the currently active spraying job.

Use

Controls on Computer

Identifies and explains the function of computer keys and switches.

Keys to Manage the Boom Sections

Explains how to select operating modes (Manual/Automatic) for boom sections.

Maintenance; Diagnostics; Repairs

Cleaning Rules

Provides guidelines for cleaning the computer and monitor safely.

Operation Errors

Lists common error messages and their corresponding causes and solutions.

Technical Data

Computer Technical Data

Specifies the technical characteristics of the BRAVO 350 computer.

Pin-out of Bravo 350

Details the connector pin assignments for various BRAVO 350 versions.

Guarantee Terms

Guarantee Terms

Outlines the warranty period, coverage, and exclusions for the apparatus.

ARAG bravo 350 Series Specifications

General IconGeneral
Display TypeLCD
CategoryControl Systems
DisplayLCD
Operating Voltage12 VDC
Housing MaterialPlastic