N80ESN/N80ESL(Series A): Installation, Start–Up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
1
Installation, Start–Up, Operating and
Service and Maintenance Instructions
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CODES AND STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCE-
DURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AIR FOR COMBUSTION AND VENTILATION . . . . . . . . . . . . 5
Table 1 – Minimum Free Area Required for Each Combustion Air
Opening or Duct to Outdoors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 2 – Minimum Space Volumes for 100% Combustion, Ventila-
tion, and Dilution from Indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
UPFLOW INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DOWNFLOW INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 3 – Opening Dimensions - In. (mm) . . . . . . . . . . . . . . . . . . 9
HORIZONTAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 9
LOCATION RELATIVE TO COOLING EQUIPMENT . . . . . . 10
AIR DUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
GENERAL REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SUPPLY AIR CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 4 – Air Delivery - CFM (With Filter)* . . . . . . . . . . . . . . . 12
Table 5 – Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
GAS PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 6 – Maximum Capacity of Pipe* . . . . . . . . . . . . . . . . . . . . 15
ELECTRICAL CONNECTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Table 7 – Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
J-BOX RELOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
NOTES FOR THERMOSTAT WIRING DIAGRAMS . . . . . . . 20
VENTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
GENERAL VENTING REQUIREMENTS . . . . . . . . . . . . . . . . 20
Table 8 – Combined Appliance Maximum Input Rating
in Thousands of Btuh per Hour . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 9 – Minimum Allowable Input Rating of Space-Heating Appli-
ance in Thousands of Btuh per Hour . . . . . . . . . . . . . . . . . . . . . . 21
EXTERIOR MASONRY CHIMNEY FAN + NAT
INSTALLATIONS WITH TYPE-B DOUBLE-WALL
VENT CONNECTORS ©NFPA & AGA . . . . . . . . . . . . . . . . . . 22
VENTING NOTES FOR Fig. 31 - Fig. 43 . . . . . . . . . . . . . . . . . 25
START-UP, ADJUSTMENT, AND SAFETY CHECK . . . . . . . . . 25
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 10 – Altitude Derate Multiplier for U.S.A. . . . . . . . . . . . . 27
Table 11Orifice Size* and Manifold Pressure (In. W.C.) for Gas In-
put Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 12 – Orifice Size* And Manifold Pressure (In. W.C.) For Gas
Input Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 13 – Gas Rate (Cu Ft./Hr.). . . . . . . . . . . . . . . . . . . . . . . . . 29
SERVICE AND MAINTENANCE PROCEDURES. . . . . . . . . . . . 30
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ELECTRICAL CONTROLS AND WIRING . . . . . . . . . . . . . . . 31
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
CLEANING AND/OR REPLACING AIR FILTER. . . . . . . . . . 32
Table 14 – Filter Size Information (In. / mm) . . . . . . . . . . . . . . . 32
BLOWER MOTOR AND WHEEL. . . . . . . . . . . . . . . . . . . . . . . 32
CLEANING HEAT EXCHANGER . . . . . . . . . . . . . . . . . . . . . . 33
SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
PARTS REPLACEMENT INFORMATION GUIDE . . . . . . . . . . . 39
CASING GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
ELECTRICAL GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
BLOWER GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
GAS CONTROL GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
HEAT EXCHANGER GROUP. . . . . . . . . . . . . . . . . . . . . . . . . . 39
INDUCER GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Portions of the text and tables are reprinted from current edition of NFPA
54/ANSI Z223.1E, with permission of National Fire Protection Association,
Quincy, MA 02269 and American Gas Association, Washington DC 20001. This
reprinted material is not the complete and official position of the NFPA or ANSI
on the referenced subject, which is represented only by the standard in its entirety.
N80ESN/N80ESL(Series A)
Single Stage, Multi-Speed ECM,
Non–Condensing Gas Furnace
Input Capacities: 45,000 Thru 155,000 Btuh
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
Question and Answer IconNeed help?

Do you have a question about the Arcoaire A Series and is the answer not in the manual?

Summary

SAFETY CONSIDERATIONS

FIRE, EXPLOSION, AND CARBON MONOXIDE HAZARDS

Warns about hazards from improper installation, adjustment, alteration, service, or use.

RELIABILITY AND CUT HAZARDS

Addresses furnace reliability and safety when handling sheet metal.

INTRODUCTION AND STANDARDS

INTRODUCTION

Provides an overview of the furnace and installation context.

CODES AND STANDARDS

Lists applicable national and local codes for installation compliance.

INSTALLATION PRECAUTIONS

ESD PRECAUTIONS

Outlines steps to prevent damage to electronic components from static discharge.

CARBON MONOXIDE HAZARD

Warns about hazards from contaminated air and corrosion of heat exchangers.

LOCATION AND AIR REQUIREMENTS

GENERAL LOCATION

Covers furnace placement, clearances, and environmental considerations.

COMBUSTION AND VENTILATION AIR

Details requirements for providing adequate air for combustion and ventilation.

INSTALLATION PROCEDURES

UPFLOW AND DOWNFLOW INSTALLATION

Provides instructions for setting up the furnace in upflow and downflow configurations.

HORIZONTAL INSTALLATION

GAS PIPING

GENERAL GAS PIPING

Covers gas supply connections, pressure testing, and code compliance.

ELECTRICAL CONNECTIONS

115-V WIRING

Guides on wiring, grounding, and connecting electrical components.

J-BOX RELOCATION

Instructions for moving the electrical junction box to an alternate location.

SERVICE AND MAINTENANCE

CARE AND MAINTENANCE

Outlines routine maintenance tasks for optimal performance and longevity.

FILTER AND BLOWER MAINTENANCE

Instructions for cleaning or replacing air filters and servicing the blower motor.

HEAT EXCHANGER CLEANING

SEQUENCE OF OPERATION

TROUBLESHOOTING GUIDE

PARTS REPLACEMENT INFORMATION GUIDE

Arcoaire A Series Specifications

General IconGeneral
Ignition SystemHot Surface Ignition
AFUE Rating80%
StagesSingle-Stage
Heat Exchanger MaterialAluminized Steel
Heating Capacity40, 000 BTU/h
WarrantyLimited Lifetime Heat Exchanger