N80ESN/N80ESL(Series A): Installation, Start–Up, Operating and Service and Maintenance Instructions
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
1
Installation, Start–Up, Operating and
Service and Maintenance Instructions
NOTE: Read the entire instruction manual before starting the
installation.
SAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
INTRODUCTION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
CODES AND STANDARDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS PROCE-
DURE. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
LOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
AIR FOR COMBUSTION AND VENTILATION . . . . . . . . . . . . 5
Table 1 – Minimum Free Area Required for Each Combustion Air
Opening or Duct to Outdoors. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Table 2 – Minimum Space Volumes for 100% Combustion, Ventila-
tion, and Dilution from Indoors . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
UPFLOW INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
DOWNFLOW INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . 8
Table 3 – Opening Dimensions - In. (mm) . . . . . . . . . . . . . . . . . . 9
HORIZONTAL INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . 9
LOCATION RELATIVE TO COOLING EQUIPMENT . . . . . . 10
AIR DUCTS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
GENERAL REQUIREMENTS . . . . . . . . . . . . . . . . . . . . . . . . . . 11
SUPPLY AIR CONNECTIONS . . . . . . . . . . . . . . . . . . . . . . . . . 11
Table 4 – Air Delivery - CFM (With Filter)* . . . . . . . . . . . . . . . 12
Table 5 – Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
GAS PIPING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Table 6 – Maximum Capacity of Pipe* . . . . . . . . . . . . . . . . . . . . 15
ELECTRICAL CONNECTIONS. . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Table 7 – Electrical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
J-BOX RELOCATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
ACCESSORIES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
NOTES FOR THERMOSTAT WIRING DIAGRAMS . . . . . . . 20
VENTING. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
GENERAL VENTING REQUIREMENTS . . . . . . . . . . . . . . . . 20
Table 8 – Combined Appliance Maximum Input Rating
in Thousands of Btuh per Hour . . . . . . . . . . . . . . . . . . . . . . . . . . 21
Table 9 – Minimum Allowable Input Rating of Space-Heating Appli-
ance in Thousands of Btuh per Hour . . . . . . . . . . . . . . . . . . . . . . 21
EXTERIOR MASONRY CHIMNEY FAN + NAT
INSTALLATIONS WITH TYPE-B DOUBLE-WALL
VENT CONNECTORS ©NFPA & AGA . . . . . . . . . . . . . . . . . . 22
VENTING NOTES FOR Fig. 31 - Fig. 43 . . . . . . . . . . . . . . . . . 25
START-UP, ADJUSTMENT, AND SAFETY CHECK . . . . . . . . . 25
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Table 10 – Altitude Derate Multiplier for U.S.A. . . . . . . . . . . . . 27
Table 11Orifice Size* and Manifold Pressure (In. W.C.) for Gas In-
put Rate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
Table 12 – Orifice Size* And Manifold Pressure (In. W.C.) For Gas
Input Rate. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Table 13 – Gas Rate (Cu Ft./Hr.). . . . . . . . . . . . . . . . . . . . . . . . . 29
SERVICE AND MAINTENANCE PROCEDURES. . . . . . . . . . . . 30
GENERAL. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
ELECTRICAL CONTROLS AND WIRING . . . . . . . . . . . . . . . 31
CARE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31
CLEANING AND/OR REPLACING AIR FILTER. . . . . . . . . . 32
Table 14 – Filter Size Information (In. / mm) . . . . . . . . . . . . . . . 32
BLOWER MOTOR AND WHEEL. . . . . . . . . . . . . . . . . . . . . . . 32
CLEANING HEAT EXCHANGER . . . . . . . . . . . . . . . . . . . . . . 33
SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34
WIRING DIAGRAM . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
TROUBLESHOOTING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
PARTS REPLACEMENT INFORMATION GUIDE . . . . . . . . . . . 39
CASING GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
ELECTRICAL GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
BLOWER GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
GAS CONTROL GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
HEAT EXCHANGER GROUP. . . . . . . . . . . . . . . . . . . . . . . . . . 39
INDUCER GROUP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39
Portions of the text and tables are reprinted from current edition of NFPA
54/ANSI Z223.1E, with permission of National Fire Protection Association,
Quincy, MA 02269 and American Gas Association, Washington DC 20001. This
reprinted material is not the complete and official position of the NFPA or ANSI
on the referenced subject, which is represented only by the standard in its entirety.
N80ESN/N80ESL(Series A)
Single Stage, Multi-Speed ECM,
Non–Condensing Gas Furnace
Input Capacities: 45,000 Thru 155,000 Btuh
Use of the AHRI Certified TM Mark indicates a
manufacturer’s participation in the program. For
verification of certification for individual products,
go to www.ahridirectory.org.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
Question and Answer IconNeed help?

Do you have a question about the Arcoaire N80ESN and is the answer not in the manual?

Summary

SAFETY CONSIDERATIONS

FIRE, EXPLOSION, ELECTRICAL SHOCK, AND CARBON MONOXIDE POISONING HAZARD

Warnings about hazards from improper installation, adjustment, or use.

ELECTROSTATIC DISCHARGE (ESD) PRECAUTIONS

ESD PRECAUTIONS STEPS

Detailed steps to prevent damage to electronic components from static discharge.

LOCATION AND AIR REQUIREMENTS

INSTALLATION PROCEDURES

DUCTS, PIPING, AND ELECTRICAL

GAS PIPING INSTALLATION

Requirements for installing gas piping according to codes and authorities.

115-V WIRING

Guidelines for 115-V wiring, voltage, phase, and circuit requirements.

VENTING REQUIREMENTS

START-UP, ADJUSTMENT, AND SAFETY CHECK

GAS INPUT RATE ADJUSTMENT

How to adjust gas input rate based on altitude and manifold pressure.

SERVICE AND MAINTENANCE

CHECK SAFETY CONTROLS

Procedures for checking limit, draft safeguard, and pressure switches.

CARE AND MAINTENANCE

Routine maintenance tasks for optimal furnace performance.

CLEANING HEAT EXCHANGER

Steps for cleaning the heat exchanger cells.

OPERATIONAL PROCEDURES

SEQUENCE OF OPERATION

Step-by-step operation during heating, cooling, and blower modes.

TROUBLESHOOTING GUIDE

Guide to diagnose and resolve furnace operational problems.

Arcoaire N80ESN Specifications

General IconGeneral
Fuel TypeNatural Gas
StagesSingle Stage
Efficiency80% AFUE
Blower MotorMulti-Speed
Ignition TypeHot Surface Ignition
Heat Exchanger MaterialAluminized Steel
Vent Size4 inches