EasyManua.ls Logo

ARDES AR6440VD - Page 40

ARDES AR6440VD
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
40 / 44
DIY fuction modes
This menu contains 9 adjustable function modes:
Mode Description
Time
(hh:mm)
Temp.
(°C)
Steam 0:05 – 6:59 50 – 110
Strengthening heating
(Back heater convection + top heater +
bottom heater)
0:05 – 3:59 100 – 230
Top heater 0:05 – 3:59 100 – 230
Top heater + Bottom heater 0:05 – 3:59 100 – 230
Hot air convection
(Top heater + Rear fan)
0:05 – 3:59 100 – 230
Back heater convection
(Back heating + rear fan)
0:05 – 3:59 100 – 230
High-temperature steaming
(Steam + Back heater convection)
0:05 – 6:59 120 – 230
Back heater convection + Rotisserie 0:05 – 3:59 100 - 230
Top heater + Rotisserie 0:05 – 3:59 100 - 230
Descaling function
Time (hh.mm)
Function
Default settings 0:50 Descaling of the evaporator
1. The descaling mixture is prepared according to the mixing ratio of 1:8 (125ml
of descaler for each litre of water) or according to the descaler instructions.
Note: use a descaler (not supplied) suitable for steam ovens..
2. Mix and put the mixture in the tank (6);
Note: The dosage of descaling mixture in the water tank may not
be lower than the MIN level marked the water tank.