FEBRUARY 2023
TEMPERATURE CONTROLS
The temperature controls are factory set to maintain an average temperature of 38F. To set a different temperature, adjust the
controls located on the front of the unit.
mute
set
Operations
Regulating the Temperature
Your new freezer or refrigerator is now manufactured to run at ideal temperatures for food quality and should
not require any alterations.
Refrigerators are set to cycle between a base temperature of 33 degrees Fahrenheit and a temperature maximum
of 40 degrees Fahrenheit.
Freezers are set to cycle between a base temperature of - 7 degrees Fahrenheit and a greatest temperature
of 0 degrees Fahrenheit.
Altering the temperature changes the base temperature your unit will keep running at. Your unit won’t run always at this
setting. To change it, take after these guidelines:
Digital Controls
Hold “SET” for 1 sec. This will show the present temperature
Use the buttons to set the temperature desired
Press “SET” again to save your settings
If the unit consistently runs 5 + degrees higher than your set temperature, service may be needed.
Note: All other control functions should be performed by a service technician.
LOADING PRODUCT
Shelves have been pre installed. Before loading shelves with products, ensure that all shelf clips are completely fastened
in their correct locations. All shelves should be completely level before stocking the cabinet with product. In order to
maintain correct air ow inside the unit, keep at least 2” to 4” of space between the back wall and the product. Blocking the
evaporator fans may cause a warmer cabinet temperature and cause damage to the compressor.
DEFROST SYSTEMS
Refrigerator coils are kept below the freezing point (32F). During compressor down time, the evaporator fan continues to
circulate air through the evaporator coil. This air circulation raises the coil temperature above the freezing point, melting any
accumulated frost. Run-off water is drained in to the evaporator pan and evaporated. Freezer coils are defrosted electrically.
Automatic defrost timers are built in to their refrigeration system and may not be adjusted. The defrost timers automatically
initiate at pre-set intervals and for a pre-determined duration.
NOTE: We strongly recommend that any servicing be performed by an authorized service technician.