REGULAR MAINTENANCE
Cleaning the Fans and Motor
Cleaning the Interior of Unit
Cleaning Condenser
For efcient operation, it is important that the condenser surface be kept free of dust, dirt, and lint.
We recommend cleaning the condenser coil and ns at least once per month.
Clean with a commercial condenser coil cleaner, available from any kitchen equipment retailer. Brush the condenser ns
from top to bottom, not side to side.
After cleaning, straighten any bent condenser ns with a n comb.
For efcient operation, it is important that the condenser surface be kept free of dust, dirt, and lint.
We recommend cleaning the condenser coil and ns at least once per month.
Clean with a commercial condenser coil cleaner, available from any kitchen equipment retailer.
Brush the condenser ns from top to bottom, not side to side.
After cleaning, straighten any bent condenser ns with a n comb.
When cleaning the cabinet interior, use a solvent of warm water and mild soap.
Do not use steel wool, caustic soap, abrasive cleaners, or bleach that may damage the stainless steel surface.
Wash door gaskets on a regular basis, preferably weekly. Simply remove door gasket from the frame of the door, soak in
warm water and soap for thirty (30) minutes, dry with soft cloth, and replace.
Check door gaskets for proper seal after they are replaced.
Periodically remove the shelves and pilasters from the unit and clean them with mild soap and warm water. To remove the
pilasters, rst remove the shelves and shelf brackets. Then, simply lift the pilaster up and out.
WARNING
If necessary, clean the fan blades and motor with a soft cloth. If it is necessary to wash the fan blades, cover the fan motor to
prevent moisture damage.
If necessary, clean the fan blades and motor with a soft cloth. If it is necessary to wash the fan blades, cover the fan motor
to prevent moisture damage.
SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
Compressor not running Blown fuse or circuit breaker
tripped
Unplugged power cord
Thermostat set too high
Cabinet in defrost cycle
Replace or reset circuit breaker
Plug in power cord
Set thermostat to lower
temperature
Wait for defrost cycle to nish
TROUBLESHOOTING
Before requesting any service on the unit, please check the following chart. Service calls resulting
from lack of maintenance or misuse is not covered under the warranty and may also void the warranty.
Please note that this guide serves only as a reference for solutions to common problems.