SYMPTOM POSSIBLE CAUSE CORRECTIVE ACTION
Condenser runs for long
Periods of time
Excessive amount of warm
Products placed in cabinet
Prolonged door opening or
door left open
Door gasket(s) not creating a
proper seal
Dirty condenser coil
Evaporator coil iced over
Allow adequate time for
Product to cool down
Ensure doors are closed.
Avoid leaving the door open
for long periods of time
Ensure gasket is installed
correctly and that it is clean
Replace gasket if necessary
Clean the condenser coil
Unplug unit and allow coil to
defrost. Ensure that the
thermostat is not set to cold
Ensure that the door gasket is
creating a proper seal
Cabinet is noisy Loose parts
Tubing Vibration
Locate and tighten loose parts
Ensure tubing is free from
contact with other tubing or
components.