17
GB
MENU
SUB-MENU
PARAMETER
DESCRIPTION RANGE NOTES
11 MULTIFUNCTIONAL P.C.B.
11 0 General
11 0 0 Function selection
0. Not defi ned
1. 3 direct zones
2. Error notifi cation and reset
3. Differential thermostat
4. Thermostat
5. Timed outlet
11 0 1 Manual mode activation ON - OFF
11 0 2 OUT1 control ON - OFF
11 0 3 OUT2 control ON - OFF
11 0 4 OUT3 control ON - OFF
11 1 Diagnostics
11 1 0 IN1 temperature -20Ð - +180Ð
11 1 1 IN2 temperature -20Ð - +180Ð
11 1 2 IN3 temperature -20Ð - +180Ð
11 1 3 OUT1 status ON - OFF
11 1 4 OUT2 status ON - OFF
11 1 5 OUT3 status ON - OFF
11 2 Differential thermostat
11 2 0 Thermostat ignition differential 0.30Ð
11 2 1 Thermostat deactivation differential 0.30Ð
11 2 2 Maximum IN1 temperature 0.130Ð
11 2 3 Maximum IN2 temperature 0.130Ð
11 2 4 Minimum IN1 temperature -20°C - +5°C
11 3 Thermostat
11 3 0 Set thermostat temperature 0.130Ð
11 3 1 Thermostat hysteresis 0.30 Ð