40
Menu - 2 - Boiler conditions
Indicates the conditions or the configurations of the boiler
5
Menu - 1 - Default register
Record the last 10 defaults
x times
once
D
ISPLAY
A
CTION
C
ONFIGURATION
N
ote
-
-
i
s displayed if no default is recorded
S
ection
D
igit 1
D
igit 2
D
igits 3 and 4
Last default occured 1 0 code from 01 to 99
L
ast but one default occurred
1 1 c
ode from
0
1
t
o
9
9
.
..
1 .
..
c
ode from
0
1
t
o
9
9
Last default occurred before the previous
one
1 9 code from 01 to 99
Section Digit 1 Digit 2 Digits 3 and 4
Software version of display PCB 2 0 code from 01 to 99
Software version of main PCB 2 1 code from 01 to 99
Flue type 2 2 4 : Condensation
Room thermostat is calling for heat 2 3
0 : No
1 : Yes
CH flow temperature in
o
C 2 7 from 01 to 99
CH return temperature in
o
C 2 8 from 01 to 99
Outside temperature
Flashing when below 0
o
C.
2 9 from 01 to 99