Supplied By www.heating spares.co Tel. 0161 620 6677
Manufacturer: Merloni TermoSanitari SpA - Italy
Commercial subsidiary: MTS (GB) LIMITED
MTS Building
Hughenden Avenue
High Wycombe
Bucks HP13 5FT
Telephone: (01494) 755600
Fax: (01494) 459775
Internet: http://www.mtsgb.ltd.uk
E-mail: info@mtsgb.ltd.uk
Technical Service Hot Line: (01494) 539579
23 99 84 1581 000 - Stampa: bieffe RECANATI
CE Certification
Heat Input max kW
Heat Output max kW
Efficiency of Nominal Heat Input %
Efficiency at 30% of Nominal Heat Input %
Heat Loss to the Casing (T=50°C) %
Flue Heat Loss with Burner Operating %
Flue Heat Loss with Burner Off %
Maximum Discharge of Fumes (G20) Kg/h
Residual Discharge Head mbar
Consumption at Nominal Capacity(G20) m
3
/h
Gas Consumption after 10 Minutes* m
3
(15°C, 1013 mbar) (G30-G31) Kg/h
Temp. of exhaust fumes at nominal capacity °C
CO
2
Content %
O
2
Content %
CO Content ppm
Minimum Ambient Temperature °C
Head Loss on Water Side (max) (T=20°C) mbar
Residual Head of System bar
Heating Temperature max/min °C
Expansion Vessel Capacity l
Expansion Vessel Pre-load Pressure bar
Maximum Water Content of System l
Maximum Heating Pressure bar
Nominal Pressure Natural Gas (G20) mbar
LPG (G30-G31) mbar
Electrical Supply V/Hz
Power Consumption W
Protection Grade of Electrical System IP
Internal Fuse Rating
Weight Kg
G.C. Number
6. TECHNICAL INFORMATION
0063BL4994
11.6
10.5
81.3
79.2
3.2
6.1
0.2
23.7
0.3
1.22
0.13
0.91/0.90
121.7
6.94
8
31.5
+5
200
0.25
82/42
6
1
130
3
20
30-37
230/50
105
X4D
FAST 2 AT
30
41-116-04
10 RFFI
*Calculated at 70% maximum output