IN CASE THE DEHUMIDIFIER MALFUNCTIONS
BEFORE CONTACTING THE TECHNICAL ASSISTANCE CENTRE, PERFORM THE FOLLOWING CHECKS
PROBLEM CAUSE SOLUTION
The appliance does not start by
pressing the ON/OFF button.
1) The plug is not properly inserted.
2) The main switch is not properly inserted.
3) The tank full indicator light is lit.
4) The tank is either full or not properly inserted.
1) Insert the plug correctly.
2) Check the main switch.
3) Empty the tank.
4) Put the tank properly back into place.
The appliance is not able to dehu-
midify the room enough.
1) The air inlet or outlet are obstructed (by cur-
tains, objects, walls, etc.).
2) The set humidity level is not low enough.
3) The windows and doors of the room are not
closed.
4) The room temperature is either too low (lower
than 5°C) or too high (above 32°C).
5) The air lter is clogged.
1) Free the air inlet and outlet.
2) Appropriately adjust the humidity lev-
el.
3) Close all windows and doors.
5) Clean the air lter.
The appliance is very noisy. 1) The air lter is clogged.
2) The appliance is inclined.
3) The appliance is resting on a non-at surface.
1) Clean the air lter.
2) Reposition the appliance.
PRODUCT TECHNICAL SHEET
Type of appliance Dehumidier
Supplier brand ARISTON
Dehumidication
(1)
litres/day 10 12
Power consumption
(1)
(max) W
230 (340) 250 (350)
Sound pressure
(1)
dB(A) 46 46
Tipo refrigerante R290 R290
Type of refrigerant
(2)
3 3
Operating temperature °C 5/32 5/32
Tank capacity litres 2.1 2.1
Power supply and no. of phases Hz - V - Ph 50-230-1 50-230-1
Type of compressor Reciprocating Reciprocating
Maximum air ow rate m3/h 107 118
Standard refrigerant charge kg /t CO2 eq. 0,045 0,05
Dimensions mm 360x253x440 360x253x440
Weight (net/gross) kg 11.4 / 12.1 11.6 / 12.1
(1) Relative to operation at 30°C and 80% relative humidity.
(2) Refrigerant loss contributes to climate change. In case of their release into the atmosphere, refrigerants with lower global warm-
ing potential (GWP) have less impact on global warming compared to refrigerants with a higher GWP. This appliance contains a
uorinated greenhouse gas, covered by the Kyoto Protocol, with a GWP of 3. In other words, if 1 kg of this uorinated greenhouse
gas were released into the atmosphere, the impact on global warming would be 3 times greater compared to 1 kg of CO, over a
period of 100 years. In no case, whatsoever must the user attempt to intervene on the refrigerant circuit or dismantle the product.
In case of need, please contact a qualied professional.