6.5.5 Removing the pump
1. Remove the electrical connection “ C1” (FIG. 6.47);
2. Release the n
ut “D1” (F
IG.
6.48);
3. Remove the retaining clip “E1” from the bottom of the
boiler (FIG. 6.49);
4. Remove the screw “F1” (FIG. 6.50);
5. Remo
ve the U-clip “G1” and remove the pressure
gauge connection (
F
IG.
6.51);
6. Remove the U-clip “H1” and remove the automatic air
vent (FIG. 6.52);
7. Remove the pump.
FIG. 6.47
C1
FIG.
6.48
D1
FIG.
6.50
FIG. 6.52
FIG. 6.51
FIG.
6.49
E1
F1
G1
H1