12
FIG 2.12
e.g. X = 508mm + 22mm = 530mm
860 - 530 = 330mm (Length to be cut from the plain
end of the flue).
Once cut to the required length, ensure that the flue is
free from burrs and reassemble the flue. If fitting the flue
from inside of the building attach the grey outer wall seal
to the flue terminal and push through the flue through the
hole
, once the wall seal has passed through the hole, pull
the flue back until the seal is flush with the wall.
Alter
natively, the flue can be installed from outside of the
building, the grey outer seal being fitted last.
FITTING THE TELESCOPIC FLUE KIT (HORIZONTAL)
CONTENTS:
1X SILICONE O-RING (60
mm)
1
X ELBOW (90
O
)
2X WALL SEALS (INTERNAL &EXTERNAL)
1X ALUMINIUM FLUE PIPE INCLUDING TERMINAL (TELESCOPIC -
60/100)
2X FLUE CLAMPS
8X SCREWS
2X FOAM SEALS
The telscopic flue is suitable for use with an exact
minimum X dimension of 270mm and an exact maximum
X dimension 470mm.
IMPORTANT!!
Do not extend the telescopic flue to an X dimension
of more than 470mm. If longer lengths are required
use extension pieces as necessary. Under no
circumstances must the flue be cut.
The wall must then be made good around the flue
(ensuring a fall of 1
o
is maintained away from the boiler to
the flue terminal).
Once made good, place the inner (white) wall seal over
the flue and push up to the w
all, secure the flue to the
elbow by using the clamp supplied.
F
or each additional 90
o
elbo
w 1 metre m
ust be removed
from the total flue length (maximum 4 metres including
the 1st elbow). For each additional 45
o
elbow 0.5 metre
must be subtracted from the total flue length (
FIG 2.13).
FITTING THE COAXIAL FLUE (VERTICAL)
(For Twin Pipe Instructions see page 13)
CONTENTS:
1X SILICONE O-RING (60mm)
1X ELBOW (90
O
)
2X WALL SEALS (INTERNAL &EXTERNAL)
1X ALUMINIUM FLUE PIPE INCLUDING TERMINAL (TELESCOPIC -
60/100)
2X FLUE CLAMPS
8X SCREWS
2X FOAM SEALS
The vertical flue kit is supplied with a specially designed
weather proof terminal fitted, it can be used either with a
flat roof or a pitched roof. (see FIGS 2.12, 2.13).
FIG 2.11
FIG 2.10
WARNING
IF
THE FLUE IS LONGER THAN
1 METRE, REMO
VE THE
RESTRICTOR (FIG. 2.11). IF THE FLUE IS BETWEEN 0-1
METRE
THE RESTRICTOR REMAINS FITTED
.
SEE TABLE 2.1 (PAGE 17).