30
NOTE: THIS TABLE CAN BE USED IN CONJUNCTION WITH THE GRAPH ON PA
GE
31.
NATURAL GAS (G20)
kW 13 15 17 19 21 23 25 27 29 31
mbar 2.5 3 3.5 4.5 5.5 6.5 7.5 8.5 10 11.5
LIQUID GAS (G30)
kW 13 15 17 19 21 23 25 27 29 31
mbar 5 7 8 10 12 14 17 20 23 27
LIQUID GAS (G31)
kW 13 15 17 19 21 23 25 27 29 31
mbar 7 9 11 13 15 18 21 24 28 34
microGENUS II 31 MFFI
NATURAL GAS (G20)
kW 10 12 14 16 18 20 22 24
mbar 2.5 3 3.75 4.75 5.75 7 8 10
LIQUID GAS (G30)
kW 10 12 14 16 18 20 22 24
mbar 5.5 8 10 12.5 15.5 18.5 22 26
LIQUID GAS (G31)
kW 10 12 14 16 18 20 22 24
mbar 7 9 12 15.5 19 24 28 34
NATURAL GAS (G20)
kW 11 13 15 17 19 21 23 25 27
mbar 2 2.75 3.5 4.5 5 6 7 8.5 10
LIQUID GAS (G30)
kW 11 13 15 17 19 21 23 25 27
mbar 5 6.5 8.5 10.5 13 15.5 18.5 21 25
LIQUID GAS (G31)
kW 11 13 15 17 19 21 23 25 27
mbar 6.5 8 10 12 14.5 17.5 21 25.5 31
microGENUS II 24 MFFI
microGENUS II 28 MFFI