Important! Before any component is removed, the boiler
must be drained of all water.
6.5.1
Removing the D.H.W. (secondary) exchanger
1.
Remove the screws “X” (FIG 6.34);
2.Disconnect the cable “Y” (FIG 6.35);
3.Push the insulation of the exchanger towards the rear
of the boiler, and lift upwards and remove from the
front of the boiler (FIG 6.36);
4.Push the exchanger towards the rear of the boiler, and
lift upwards and remove out of the front of the boiler
(FIG 6.37);
5.Before replacing the exchanger ensure that the O-rings
are in good condition and replace if necessary.
6.5 ACCESS TO THE WATER CIRCUIT
FIG. 6.34
X
X
FIG.
6.35
FIG. 6.36
FIG. 6.32
FIG.
6.33
W
W
6.4.2 Removing the gas valve (Honeywell)
Important! Before removing the gas valve, ensure the
gas supply is tur
ned off.
1. Disconnect all the cables from the solenoid and
modureg;
2. Remo
ve the spark generator (see previous section);
3. Release the n
uts “V” (F
IG.
6.31);
4. Remove the screws “W” from the bottom of the gas
valve (FIG. 6.32);
5. Remove the gas valve (FIG. 6.33).
FIG. 6.31
V
V
Y