NEW INVERTER ERROR TABLE FOR ODU 9-11 1-PHASE
ERRORI
INVERTER
DESCRIZIONE 1PH
1
ERRORE SENSORE CORRENTE U DEL COMP
x
2 ERRORE SENSORE CORRENTE V DEL COMP x
3 ERRORE SENSORE CORRENTE W DEL COMP x
4 ERRORE SENSORE CORRENTE PFC x
5 ERRORE SENSORE TEMPERATURA IPM x
6
ERRORE SENSORE TEMPERATURA PFC
x
7 ERRORE SENSORE DLT x
8 ERRORE PERDITA DI COMUNICAZIONE x
9 ERRORE EEPROM x
10
ERRORE SOVRACORRENTE AC
x
11
ERRORE SOVRATENSIONE AC
x
12 ERRORE SOTTOTENSIONE AC x
13 ERRORE SOVRATENSIONE DC x
14 ERRORE SOTTOTENSIONE DC x
15
ERRORE ALTA PRESSIONE
x
16 ERRORE PERDITA FASE D'INGRESSO x
17 ERRORE SURRISCALDAMENTO IPM x
18 ERRORE SURRISCALDAMENTO IGBT x
19
ERRORE CODICE COMPRESSORE
x
20
SOVRATENSIONE HW DEL COMP
x
21 SOVRACORRENTE DELLA FASE U DEL COMP x
22 SOVRACORRENTE DELLA FASE V DEL COMP x
23 SOVRACORRENTE DELLA FASE W DEL COMP x
24
PERDITA DI FASE DEL COMPRESSORE
x
25 PERDITA DEL PASSO DEL COMPRESSORE x
26 FALLITA PARTENZA DEL COMPRESSORE x
27 SBILANCIAMENTO FASE DELLA CORRENTE DEL COMPRESSORE x
28
SOVRACCARICO DEL COMPRESSORE
x
29
SURRISCALDAMENTO DLT COMPRESSORE
x
30 PROTEZIONE IN SEGUITO A DEMAGNETIZZAZIONE IPM x
31 SOVRATENSIONE DEL HW DEL PFC x
32 SOVRATENSIONE DEL SW DEL PFC x
33
SOVRATENSIONE DEL PFC
x
34 ERRORE AD x
35 ERRATO INDIRIZZAMENTO x
36 VELOCITà MINORE DI ZERO x
37
CORRENTE DEL COMPRESSORE NON VARIA
x
38
FREQUENZA DELLA CORRENTE NON CORRISPONE A CALCOLO VELOCITà
x
39 VARIAZIONE TROPPO REPENTINA DELLA CORRENTE DEL COMPRESSORE x
40 TENTATIVO FALLITO NEL FAR PARTIRE LE VENTOLE x
41 PROTEZIONE IN SEGUITO AD ALTA PRESSIONE x
42
PROTEZIONE IN SEGUITO A BASSA PRESSIONE
x
43 PROTEZIONE IN SEGUITO AD ATTIVAZIONE KLIXON TESTA COMPRESSORE x