REMOTE CONTROL DEVICE TECHNICAL DATA
Power supply BUS
Electrical absorption max. < 0.5W
Operating temperature -10 to 60°C
Storage temperature -20 to 70°C
Bus wire length and cross-sectional area
NOTE: IN ORDER TO AVOID INTERFER
ENCE PROBLEMS, USE A SHIELDED CA
BLE OR TWISTED PAIR CABLE.
max. 50 m
min. 0.5 mm²
Buer memory 2 h
Conformity
LVD 2006/95/EC - EMC 2004/108/EC
Electromagnetic interference EN 60730-1
Electromagnetic emissions EN 60730-1
Conformity to standards EN 60730-1
Temperature sensor NTC 5 k 1%
Resolution degree 0.1°C
134 mm 16 mm
96 mm
REMOTE CONTROL DEVICES OUTDOOR SENSOR
Position the outdoor sensor on the north-facing wall of the build-
ing, at least 2.5 m from the ground and away from direct sunlight.
Remove the cover (fig. A) and install the sensor using the rawl
plug and screw provided (fig. B).
Make the connection using a 2x0.5 mm
2
cable.
Maximum connection length 50 m.
Connect the wire to the terminal (fig. C) by introducing it from the
lower part after creating a suitable passage.
Place the sensor cover back in the correct position.
A B C
PRODUCT FICHE
SUPPLIER’S NAME ARISTON
SUPPLIER’S MODEL IDENTIFIER SENSYS OUTDOOR SEN-
SOR
Class of the temperature control VI
Contribution to seasonal space heating energy eciency in % +4%
In a 3-zones system with 2 Ariston Room Sensors
Class of the temperature control VIII --
Contribution to seasonal space heating energy eciency in % +5% --