12.9.7 External Boiler Eciency DHW
Defines the estimated average yield of the AUX 1/2 boiler in DHW pro-
duction mode.
Premere il tasto OK.
12.9.8 DeltaT obbiettivo x COP
Defines the estimated heat exchange in degrees to estimate the com-
pressor’s yield in heating mode.
Turn the knob and select:
12.10 ENERGY MANAGER STATISTICS
Displays information relative to the system’s total hours of operation.
Turn the knob and select:
12.11 ENERGY MANAGER INFO
Displays information relative to the energy costs totalled by the system.
Turn the knob and select:
12.12 HP DIAGNOSTICS - 1
Turn the knob and select:
12.13 HP DIAGNOSTICS - 2
Displays the values of the main features of the heat pump.
Turn the knob and select:
12.14 HP DIAGNOSTICS - 3
Displays the values of the main features of the heat pump.
Turn the knob and select:
12.15 HP DIAGNOSTICS - 4
Displays the values of the main features of the heat pump.
Turn the knob and select:
12.16 EM DIAGNOSTICS - 1 INPUT
Displays the values of the system’s board inputs.
Turn the knob and select:
12.17 EM DIAGNOSTICS - 2 INPUT
Displays the values of the system’s board outputs.
Turn the knob and select:
12.18 ERROR HISTORY
Displays the last 10 errors.
Turn the knob and select:
12.19 RESET MENU
Deletes the factory settings.
Turn the knob and select:
19 CONNECTIVITY
Press the OK button.
After checking the availability of the Sensys NET service in your country,
follow the instructions in the Sensys NET
ELECTRICITY/GAS COSTS
Our system allows to insert cost values in a range between 0.1-99.9, independently from the local currency in use in the
country of installation. We recommend to always insert comparable costs for electricity and gas (please see below, only
indicative values for electricity and natural gas).
Installation Area
Recommended
cost unit
Cost examples (average values, could dier considerably from real
ones)
Value to input
Euro Area €cent
Gas kWh cost 0,065 EUR 6.5
Electricity kWh cost 0,220 EUR 22.0
United Kingdom pence
Gas kWh cost 0,047 GBP 4.7
Electricity kWh cost 0,177 GBP 17.7
Hungary HUF
Gas kWh cost 11,486 HUF 11.5
Electricity kWh cost 36,709 HUF 36.7
If input costs are not in line with ratios selected through parameters 12.9.0 and 12.9.1, the system goes into error mode.
NOTE: to insert correct parameters inside menu 12.9 is fundamental to get an ecient system operation. We recommend
to insert actual values gathered from electricity/gas bills for the specific application (simply, the ratio between expense
for energy and kWh consumption in a certain amount of time).
If no historical baseline data are available, we recommend to insert standard costs for the country where the system
is installed. A few average values for electricity and natural gas following (Eurostat data, 1st half of 2017, source: http://
ec.europa.eu/eurostat); warning: they could dier considerably from real costs.
GAS kWh COST ELECTRICITY kWh COST PAR. 12.9.3 PAR. 12.9.4
Italy 0,070 EUR 0,214 EUR 7.0 21.4
France 0,064 EUR 0,169 EUR 6.4 16.9
Germany 0,061 EUR 0,305 EUR 6.1 30.5
Netherlands 0,076 EUR 0,156 EUR 7.6 15.6
Belgium 0,052 EUR 0,280 EUR 5.2 28.0
Austria 0,067 EUR 0,195 EUR 6.7 19.5
Denmark 0,603 DKK 2,272 DKK 6.0 22.7
Hungary 11,486 HUF 36,709 HUF 11.5 36.7
United Kingdom 0,041 GBP 0,156 GBP 4.1 15.6