77 / GB
MENU
SUB-MENU
PARAMETER
DESCRIPTION
RANGE DEFAULT
558Target deltaT for pump modulation cooling [-5; -20°C]
-5°C
7 ZONE MODULE (if present)
7 1 Manual Mode
7 1 0 ZM Manual mode activation OFF - ON OFF
7 1 1 Z1 Pump control OFF - ON OFF
7 1 2 Z2 Pump control OFF - ON OFF
7 1 4 Z2 Mix Valve Control
OFF
Open
Close
OFF
7 2 General Zone Module
720Hydraulic scheme de nition
Not de ned
MCD
MGM II
MGM III
MGZ I
MGZ II
MGZ III
MGM II
721FlowT O set 0
722Auxiliary output setting
Heat request
External pump
Alarm
Heat request
723External temperature correction - 3 ÷ +3°C 0°C
7 3 Cooling
730Flow_T_o set_Cool [ 0÷ 6°C]
0°C
7 8 Error History
7 8 0 Last 10 Errors
781Reset Error List Reset? OK=Yes,esc=No
7 8 2 Last 10 Errors 2
783Reset Error List 2 Reset? OK=Yes,esc=No
7 9 Reset Menu
790Reset Factory Settings Reset? OK=Yes,esc=No
17 HP System Parameters
17 0 User Parameters
17 0 0 CH mode
Mode Green
Mode Standard
Mode Green
17 0 1 Quiet Mode Activation OFF - ON OFF
17 0 2 Quiet Mode start time [hh:mm] [00:00-24:00] 22:00
17 0 3 Quiet Mode end time [hh:mm] [00:00-24:00] 06:00
17 0 4 Domestic Hot Water BOOST OFF - ON OFF
17 0 5 PV Delta T DHW setpoint temp. 0 ÷ 20°C 0°C
17 1 EM Input Output Con guration
17 1 0 HV Input 1
Not De ned
Absent
EDF
SG1
Absent
17 1 1 HV Input 2
Not De ned
Absent
DLSG
SG2
Absent
17 1 2 HV Input 3
Not active
PV Integration Active
Not active