Heat pump water heater – GENERAL INFORMATION
32
PERFORMANCES
measurement
150 L 200 L 300 L
COP (*) 3,1 3,1 3,1
Heating time with heat pump (*) h:min 3:00 4:00 6:24
Heating energy consumption (*) kWh 2,0 2,58 4,28
hot water in a
single intake V
40
(**)
Delivered at 51°C
l 180 260 426
Delivered at 62°C
l 230 318 549
Max. water temperature with heat
pump
°C
62 (55 factory default
setting)
62 (55 factory default
setting)
62 (55 factory default
setting)
Max. water temperature with
heating element
°C
75 (65 factory default
setting)
75 (65 factory default
setting)
75 (65 factory default
setting)
QPr (over 24h) KWh 0,49 0,52 0,63
Power source
Voltage / max. power consumption
(*)
V / W 220-240 single-phase / 2500
Frequency Hz 50
Max. current consumption A 10,8
(*) values obtained with air temperature of 7°C, 87% relative humidity and input water temperature of 15°C (in
conformity with the NF Cahier de Charge standard).
(**) Performance measured for heating of water between 15°C and 51°C with a temperature for the aspirated air of 15°C and 70%
relative humidity, in compliance with the cahier des charges of the NF Electricitè performance N°LCIE 103-15 mark relative to
independent storage water heaters.
(***) outside of the heat pump’s interval of operation, heating of the water is ensured by the heating element..
Average value obtained on a significant number of products.