BRIDGENET BUS BOILER DIAGRAM 2 DIRECT ZONES, 4 LOW TEMPERATURE ZONES
AND DOMESTIC HOT WATER STORAGE CYLINDER
RVS 2 MENU PARAMETER DESCRIPTION VALUE
Engineer
Confi guration 5715
Heating circuit 2
(zone 5 activation)
On
Engineer
Confi guration 5890
Relay output QX1
(activation of zone 6 management)
Heat circuit pump HCP Q20
Engineer
LPB 6600 Device address 2
Engineer
LPB 6640 Clock mode Slave without remote setting
RVS 1 MENU PARAMETER DESCRIPTION VALUE
Engineer
Confi guration 5715
Heating circuit 2
(zone 2 activation)
On
Engineer
Confi guration 5890
Relay output QX1
(activation of zone 3 management)
Heat circuit pump HCP Q20