5.
MAINTENANCE
To
ensure
efficient
and
safe
operation,
and
to
maintain
the
warranty,
it
is
necessary
to
ensure
the
appliance
is
serviced
annually
by
a
competent
person.
Before
servicing,
preliminary
electrical
system
checks
must
be
carried
out
to
ensure
electrical
safety
(i.e.
polarity,
earth
continuity,
resistance
to
earth
and
short
circuit).
5.1
ProTech
Anti-corrosion
System
WARNING:
SWITCH
OFF
THE
POWER
SUPPLY
BEFORE
WORKING
ON
THE
APPLIANCE.
Trouble-shooting:
1)
The
green
L.E.D.
is
NOT
on:
-
Check
to
see
that
the
circuits
electric
plug
is
connected
(if
not,
connect);
-
Check
to
see
that
the
P.C.B,
is
supplied
with
electricity
(if
not,
replace
the
supply
cable);
-
Check
to
see
that
230
V
electricity
is
supplied
(if
not,
ensure
that
230
V
is
supplied);
-
If
all
these
checks
fail
to
locate
the
problem,
replace
the
electronic
circuit
(installer).
2)
The
red
L.E.D.
is
on:
-
Check
to
see
that
the
tank
is
filled
with
water
(if
not,
fill
it
before
carrying
out
the
following
checks);
-
Check
to
see
that
the
clip-on
circuit
connector
is
in
the
proper
position
(if
not,
position
correctly);
-
Check
to
see
that
the
electrodes
connection
lead
is
property
connected
(to
check
this,
gently
pull
on
it)
(if
not,
replace
the
electrode);
-
Check
to
see
that
the
connection
lead
to
the
tank
is
properly
connected
to
the
tank
(if
not,
connect
properly);
.
-
Check
to
see
thait
the
two
leads
from
the
clip-on
circuit
connector
are
not
damaged,
stripped,
etc.
(if
so,
replace
the
electrode);
-
If
all
these
checks
fail
to
locate
the
problem,
replace
the
electronic
circuit.
Note:
To
replace
the
RC.B,
there
is
no
need
to
drain
the
cylinder;
1)
Disconnect
the
two
supply
cables
from
the
P.C.B.
to
the
supply
terminal;
2)
Disconnect
the
clip-on
circuit
connector
and
polarising
slot
which
connects
the
circuit
to
the
tank
and
the
electrode;
3)
Disconnect
the
P.C.B.
from
its
supporting
plate
(plastic
clips
in
the
4
corners)
and;
4)
Replace
the
defective
circuit
with
a
new
one,
then
re-install
in
reverse
order
to
the
above.
5.2
Thermal
Cut-out(s)
If
the
thermal
cut-out
has
operated
the
cause
must
be
found
before
resetting
(see
section
6).
5.3
Immersion
Heater(s)
Should
the
immersion
heater(s)
become
scaled,
we
would
recommend
that
the
immersion
heaters
be
replaced,
a
scale
reducer
be
fitted
on
the
cold
water
supply
to
the
cylinder
and
that
the
thermostat
is
set
below
60°C
to
prevent
further
scale
formation.
5.4
Unvented
Controls
26
Check
controls
as
per
the
following:
1)
Line
strainer
-
with
the
water
supply
turned
off
remove
screen
from
strainer
and
clean
off
any
debris;
2)
Expansion
vessel
-
with
the
water
supply
turned
off
and
taps
open,
check
expansion
vessel
pressure
and
top
up
as
necessary;
3)
Temperature
&
pressure
relief
valve
-
with
the
water
supply
turned
on,
check
manually
by
lifting
the
test
lever/turning
the
test
knob
(ensure
valve

Other manuals for Ariston ST 100 ProTech

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston ST 100 ProTech and is the answer not in the manual?

Ariston ST 100 ProTech Specifications

General IconGeneral
BrandAriston
ModelST 100 ProTech
CategoryWater Heater
LanguageEnglish

Related product manuals