closes
after
testing):
4)
Expansion
relief
valve
-
check
manually
by
turning
the
test
knob
(ensure
valve
closes
after
testing);
5)
Discharge
pipes
(D1)
-
from
both
temperature
&
pressure
relief
and
expansion
relief
valve
for
obstructions;
6)
Tundish
&
discharge
pipe
(D2)
-
open
either
valve
gradually
to
produce
a
full
bore
discharge
Into
tundish
and
D2
without
any
back
pressure;
7)
Pressure
reducing
valve
-
check
that
the
correct
outlet
pressure
Is
being
maintained
by
recording
the
pressure
at
an
In-line
terminal
fitting
e.g.
tap.
5.5
Thermostats
Ensure
that
all
thermostats
are
adjusted
for
the
correct
temperature
setting,
this
should
be
between
60
and
65°C.
5.6
Maintenance
Procedure
To
ensure
efficient
and
safe
operation,
and
to
maintain
the
warranty,
It
Is
necesary
to
ensure
the
appliance
Is
serviced
annually
by
a
competent
person.
After
servicing,
preliminary
electrical
system
checks
must
be
carried
out
to
ensure
electrical
safety
(I.e.
polarity,
earth
continuity,
resistance
to
earth
and
short
circuit).
To
drain
the
cylinder
It
Is
necessary
to
proceed
as
follows:
1)
Close
the
mains
supply
service
valve;
2)
Open
hot
water
taps;
3)
Attach
a
hose
and
open
the
drain
cock
and
allow
the
cylinder
to
empty.
Magnesium
Anodes
(STD
and
STI
models
only)
No
longer
than
every
12
months,
the
installer
should
check
the
magnesium
anti-corrosion
anodes
(consult
the
label
on
the
face
of
the
unit
for
the
correct
location).
Assessment
of
the
condition
of
the
bottom
anode
(where
fitted)
can
be
made
by
judging
the
condition
of
the
top
anode.
Removal
of
anodes;
1)
Close
the
mains
supply
service
valve;
2)
Open
hot
water
taps;
3)
Attach
a
hose
and
open
the
drain
cock
and
allow
the
cylinder
to
empty;
4)
The
anodes
are
removed
by
unscrewing;
EXAMINE
THE
ANODES
AND
IF
THE
DIAMETER
IS
LESS
THAN
10mm
replace
both
anodes.
The
use
of
an
approved
P.T.F.E.
sealing
tape
Is
required
to
ensure
watertight
connection
for
anodes.
Thermal
Cut-out(s)
If
the
thermal
cut-out
has
operated
the
cause
must
be
found
before
resetting.
Immersion
Heater(s)
Should
the
Immersion
heater
be
scaled,
we
would
recommend
It
be
replaced.
Mim

Other manuals for Ariston ST 100 ProTech

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ariston ST 100 ProTech and is the answer not in the manual?

Ariston ST 100 ProTech Specifications

General IconGeneral
BrandAriston
ModelST 100 ProTech
CategoryWater Heater
LanguageEnglish

Related product manuals