Summary

Assembly and Operation Instructions

General Safety Instructions

Qualified Personnel for Installation

Installation and maintenance must be performed by qualified personnel using original spare parts for safety.

Mandatory Safety Valve Installation

Mandatory installation of a safety valve on the water inlet pipe according to national regulations.

Legionella Bacteria Function

Technical Characteristics

Compliance and Directives

Confirms compliance with international electrical standards and EC directives for safety and performance.

Building Regulations

Unvented System Installation Rules

Installation of unvented systems over 15L is a 'Controlled Service' under Regulation G3, requiring notification.

Installing Norms (for the installer)

Pre-installation Requirements Check

Installer must read instructions, contact technical service if unsure, and check water regulations.

Installation Guidelines

Vertical Installation Verification

The appliance must be installed vertically for correct operation. Check with a spirit level.

Discharge Pipe Work Guidelines

Building Regulation G3 Compliance

Guidelines for relief valve discharge pipe work according to Building Regulation G3.

Draining the Appliance

Procedure for Appliance Draining

Steps to drain the appliance for inactivity or frost protection, including turning off power and supplies.

Electrical Warning and Installation

Earthing and Wiring Compliance

Appliance must be earthed; electrical installation must comply with I.E.E. wiring regulations.

Power Supply and Cable Specifications

Requires 240 VAC, 3 kW supply; specifies cable type and connection methods.

Commissioning Procedure

Electrical System Verification

Mandatory check of electrical system compliance for safety and adequate power supply.

Power Supply and Grounding Checks

Check power rating matches nameplate; prohibit multi-plugs; ensure proper grounding.

Component and Plumbing Inspection

Verify all necessary components are supplied and undamaged, and discharge pipe is correctly plumbed.

Maintenance Regulations (for qualified personnel)

Pre-Maintenance Safety Checks

Before maintenance, check for water/power failure and disconnect appliance from mains.

Replacing Components and Parts

Instructions for accessing and replacing electrical parts, control panel, sensors, heating elements, and anodes.

Periodic Maintenance Schedule

Recommendations for descaling heating elements (every 2 years) and replacing magnesium anodes (every 2 years).

User Instructions

User Advice and Safety Warnings

Avoid positioning objects near leaks; disconnect if unused; hot water can cause burns; user maintenance is forbidden.

ECO EVO Function Explained

Explains the ECO EVO function for learning consumption patterns and saving energy.

Specific Appliance Functions

Thermal Disinfection Function Activation

Activates a 60°C cycle for 1 hour to prevent Legionella bacteria; can be activated manually.

Wi-Fi Connectivity Setup

Account and App Setup Procedure

Steps for creating an account and downloading the Aqua Ariston NET App for remote control.

Wi-Fi Network Configuration Steps

Procedure to connect the appliance to the Wi-Fi network or create an Access Point.

Troubleshooting and Useful Information

Common Water Issues and Checks

Checks for cold water, boiling hot water, insufficient hot water, and water trickling from the safety device.

Overview

This document provides comprehensive assembly and operation instructions for an unvented water heater, emphasizing safety, proper installation, and maintenance. The device is designed to provide hot water for domestic use, incorporating features for energy efficiency and user convenience.

Function Description

The unvented water heater is an appliance designed to heat and store water for domestic use. It operates by heating water to a temperature below boiling point and is connected to a mains water supply. A key feature of this water heater is its unvented design, which means it operates under mains pressure, providing hot water at a consistent flow rate to multiple outlets simultaneously.

The device includes a thermal disinfection cycle function, enabled by default, to prevent the growth of Legionella bacteria. This cycle heats the water to 60°C for a specified period, typically when the product is switched on, restarted after a power outage, or every 30 days if the water temperature consistently remains below 55°C. This ensures hygienic water delivery.

For enhanced energy efficiency, the water heater is equipped with an "ECO EVO" function. This intelligent software program learns user consumption patterns over time, minimizing heat loss and maximizing energy savings. It adapts water heating schedules to the user's actual needs, ensuring a minimum reserve of hot water is always available while optimizing energy consumption. The learning process typically takes a week initially, with maximum efficiency achieved after four weeks.

A "Shower Ready" function is also available on some models, designed to minimize water heating time. This feature indicates when enough hot water is available for at least one shower (40 liters of mixed hot water at 40°C), regardless of the user's set temperature.

The anti-freeze function provides automatic protection against damage caused by very low temperatures (below 5°C), even when the product is turned off during winter. For this function to operate, the product must remain plugged into the mains power.

Usage Features

The water heater offers a user-friendly interface for temperature adjustment and function activation. Users can switch the appliance on/off using a dedicated button and set the desired water temperature between 40°C and 65°C using "+" and "-" buttons. During the heating phase, LEDs on the control panel indicate the temperature reached, with subsequent LEDs flashing progressively until the set temperature is achieved. If the temperature drops, the heating reactivates automatically, and the LEDs resume their progressive flashing.

The "ECO EVO" function can be activated by pressing its corresponding button, which will illuminate. While in ECO EVO mode, manual temperature selection is still possible, but changing the temperature will temporarily disable the ECO EVO function. It can be reactivated by pressing the ECO button again. The system retains learned consumption levels even if the product is turned off and on, provided it remains connected to the mains power for up to four hours. To voluntarily reset the acquired data, users can hold down the "ECO" button for more than 5 seconds.

For models with Wi-Fi functionality, users can connect the water heater to their home network via a dedicated app. This allows for remote control and monitoring of the device. The Wi-Fi button on the control panel is used to activate Wi-Fi (blinking slow) and create an Access Point (blinking fast) for initial setup. The app guides users through account creation, product registration, and connection to the home network, providing remote access to functions like on/off, manual mode, program mode, ECO mode, power settings, temperature selection, remaining time, and number of showers. LED indicators on the Wi-Fi button provide status updates (blinking slow for connected to home network, blinking fast for Access Point mode, steady on for connected and ON, off for module OFF).

Maintenance Features

Maintenance of the unvented water heater should only be performed by professionally qualified personnel. Before any maintenance work, it is crucial to disconnect the appliance from the mains power.

Regular maintenance includes descaling the heating element, which should be done approximately every two years, or more frequently if the water is very hard. This helps ensure proper functioning and efficiency. Magnesium anodes, present in most models (except those with stainless steel boilers), should be replaced every two years. However, an annual check is recommended if the water is corrosive or rich in chloride. Replacing anodes involves removing the heating elements and unscrewing them from their brackets.

The bypass pipe should be inspected in case of obstruction, which involves removing two rings. After any routine or extraordinary maintenance, it is recommended to fill the tank with water and drain it completely to remove any residual impurities. Only original spare parts supplied by the manufacturer's authorized service centers should be used for replacements.

The electrical parts, including the power board, control panel, and rod carrying sensors, can be accessed by removing the cover. Specific instructions are provided for disconnecting cables and removing components, with emphasis on careful handling to avoid damage, especially to plastic flaps during control panel removal. During reassembly, all components must be returned to their original positions, and the flange gasket should be replaced every time it is disassembled. It is critical not to reverse the heating elements, as this can cause appliance malfunction; work on one heating element at a time.

For troubleshooting, if the water comes out cold, checks should include the presence of voltage, the circuit board, heating parts, bypass pipe, and sensor holder rods. If the water comes out boiling hot, the circuit board, amount of scale, and sensor holder rods should be checked after disconnecting the electricity supply. Insufficient hot water delivery may indicate issues with mains water pressure, the cold water intake pipe deflector, the hot water pipe, or electrical components. Water trickling from the pressure safety device is normal during heating but persistent trickling may require checking device calibration and mains water pressure. The appliance outlet should never be obstructed. In case of persistent problems, users are advised not to attempt repairs themselves but to contact a qualified technician.