16
Load Mode Settings
Enter Load SET Mode by pressing the Setting key in Load Mode view only.
Use the arrow key to cycle through load modes before long pressing SET to save and exit. Short pressing SET will exit
without saving.
Mode
Definition
Description
0
Daylight Auto-Control
DC load turns on when no daylight is detected.
1~14
Daylight On/Timer Off
DC load turns on when no daylight is detected.
DC load turns off according to timer.
15
Manual Mode
DC load turns on/off by pressing the Return key.
16
Testing Mode
DC load turns on and off in a quick succession.
17
Always On
DC load stays on.