77
Current
Voltage
22A
525V
Protection Features
OC, OV, OT, OP, RV
Reverse Current Capacity
Input OFF
Input ON
25A
35A
Ripple and Noise
Current(rms/p-p)
Voltage(rms)
3mA/30mA
30mV
Environmental Conditions
Temperature
Relative Humidity
050ºC
85%
Remote Interface
*6
RS232, GPIB, USB
Programming Language
SCPI
AC Input
Voltage
Frequency
AC110V or AC220V±15%
48 to 63Hz
Net Weight
5.8kg
*1. Maximum continuous power available is derated linearly from 100% of maximum at
40ºC, to 75% of maximum at 50 ºC.
*2. Conductance (S) = 1 / Resistance (Ω). The siemens is the SI derived unit of
conductance, and the symbol is "S".
*3. The set level is 10 times larger than the slew rate in CCL mode.
*4. The actual transition time is defined as the time required for the input to change from
10% to 90% or from 90% to 10% of the programmed excursion.
*5. Transient frequency depends on the time for high/low level and rising/falling edge.
*6. Full remote control via RS232 with optional GPIB and USB.