PowerMaster II RF Wattmeter www.arraysolutions.com Rev 4.1 - February 23, 2017
SPECIFICATIONS - Specifications subject to change without notice. ( Applies to 3 kW model, similar specs for 10 kW)
50 ohms nominal, <1.05 VSWR insertion
SO-239 female (Type-N, and 7/16 DIN optional)
1 to 3005 watts (3 kW HF)
1 to 9999 watts (10 kW HF) - Limited by VSWR to the limits of the connector
< ±3% as measured against NIST traceable calibrated instruments (see accuracy
section on how to achieve better accuracy)
12 Bit A/D – 4 overlapping channels of auto ranging = 14 Bit effective resolution
VSWR Alarm Relay Actuation time
Off, 1.5, 2.0, 2.5, 3.0 – relay programmable to open or close on trip
Off, 5, 50, 100, 250, 500, 1000, 2000 watts - NC and NO relay contacts are
available
Off, 175, 225, 700, 1100, 1600, 2600, 3000
Manual front panel (stand alone) or via RS232/USB – application software
-31°F to 122°F (-35°C to +50°C)
Regulatory Testing and Certification
Exceeds FCC Class B (tested) and CE - both emissive and conductive (tested) as
well as EMP 4 kV and 8 kV on cables
Display 8 ¼” X 3 ½ “Face, 4 ¼” Deep
Coupler 2 ¾” X 2 ¾” X 6 ½”