EasyManua.ls Logo

Array Solutions PowerMaster II - Specifications

Array Solutions PowerMaster II
28 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PowerMaster II RF Wattmeter www.arraysolutions.com Rev 4.1 - February 23, 2017
27
SPECIFICATIONS - Specifications subject to change without notice. ( Applies to 3 kW model, similar specs for 10 kW)
Frequency Range
1 30 MHz, 50 - 54 MHz
Line Impedance
50 ohms nominal, <1.05 VSWR insertion
Insertion Loss
0.05 dB or less
Line Connections
SO-239 female (Type-N, and 7/16 DIN optional)
Power Ranges
1 to 3005 watts (3 kW HF)
1 to 9999 watts (10 kW HF) - Limited by VSWR to the limits of the connector
VSWR Range
1.00 to 99.00
Accuracy
< ±3% as measured against NIST traceable calibrated instruments (see accuracy
section on how to achieve better accuracy)
Resolution
12 Bit A/D 4 overlapping channels of auto ranging = 14 Bit effective resolution
Peak Power Capture Time
< 5 milliseconds
VSWR Alarm Relay Actuation time
< 30 milliseconds
Bar Graph Response
> 20 Hz
VSWR Alarm
Off, 1.5, 2.0, 2.5, 3.0 relay programmable to open or close on trip
Low Power Monitor Alarm
Off, 5, 50, 100, 250, 500, 1000, 2000 watts - NC and NO relay contacts are
available
High Power Monitor Alarm
Off, 175, 225, 700, 1100, 1600, 2600, 3000
Alarm Relay Contacts
0.5 A, 50 volts AC/DC
Control
Manual front panel (stand alone) or via RS232/USB application software
Power Required
12 15 V DC at 300 mA
Temperature of Operation
-31°F to 122°F (-35°C to +50°C)
Regulatory Testing and Certification
Exceeds FCC Class B (tested) and CE - both emissive and conductive (tested) as
well as EMP 4 kV and 8 kV on cables
Dimensions
Display 8 ¼” X 3 ½ “Face, 4 ¼” Deep
Coupler 2 ¾” X 2 ¾” X 6 ½”
Shipping Weight
4 lb (1.8 kg) .