Protocol
65
Mode 16 / 17: GEL, gel selection
Category 1, Rosco, Color correction
Category 1, Rosco, Color correction, continued
14
0-255 0-100
Gel 2
See tables below
15
0 – 51
52 – 102
103 – 153
154 – 204
205 - 255
0 – 20
21 – 40
41 – 60
61 – 79
80 - 100
Gel Transition Type
Direct
Through White Point
Through Black Point
Over White Point
Under White point
16
Reverts to
fixture set-
ting when
signal lost.
0-9
10-60
61-120
121-180
181-250
251-255
0-4
5-23
24-47
48-70
71-98
99-100
Fan Control
No function
Low
Variable
High
Fan max. speed
Fan off
17-19 Reserved (only V4.x)
Chan. Value Gel name Number
6
0 - 1
2 - 3
4 - 5
6 - 7
8 - 9
10 - 11
12 - 13
14 - 15
16 - 17
18 - 19
20 - 21
Full CTB
3/4 CTB
1/2 CTB
1/3 CTB
1/4 CTB
1/8 CTB
Double CTB
Full CTO
3/4 CTO
1/2 CTO
1/4 CTO
3202
3203
3204
3206
3208
3216
3220
3407
3411
3408
3409
Channel Value Percent Function
Chan. Value Gel name Number
6
22 - 23
24 - 25
26 - 27
28 - 29
30 - 31
32 - 33
34 - 35
36 - 37
38 - 39
40 - 41
42 - 43
44 - 45
46 - 47
48 - 49
50 - 51
52 - 53
54 - 55
56 - 57
58 - 59
60 - 61
62 - 63
64 - 65
66 - 255
1/8 CTO
Double CTO
Full CTS
1/2 CTS
1/4 CTS
1/8 CTS
Full Plusgreen
1/2 Plusgreen
1/4 Plusgreen
1/8 Plusgreen
Full Minusgreen
3/4 Minusgreen
1/2 Minusgreen
1/4 Minusgreen
1/8 Minusgreen
Fluorofilter
Industrial Vapor
Urban Vapor
Tough Y-1
Tough MT 54
Tough MTY
Tough MT2
Reserved
3410
3420
3441
3442
3443
3444
3304
3315
3316
3317
3308
3309
3313
3314
3318
3310
3150
3152
3107
3134
3106
3102