11
Start Using Your Appliance
CAGH6000B
CAGH7000B,
CAGH9000B
Description Explanation
Zone indicators
These show which zone is under control.
Flame power
Flame power of the zones, is the lowest and
is the highest.
The hotplates are fitted with mains powered electronic spark ignitors, so must be connected to mains power
supply (i.e. nominal 220~240 V ac) to operate. If power is not available, the hotplate will still work but the burners
will have to be lit with a match or similar.
Depressing the gas control knob of any burner will activate the spark ignition for all burners. To light the burner,
turn the gas control knob to the High Flame setting of the burner to be lit, while at the same time depressing the
gas control knob to activate the spark ignition.
Once the burner is light, continue to depress the gas control knob for 5 – 10 seconds to allow the flame
safeguard to activate. If when you release the gas control knob, the burner flame goes out the flame safeguard
has not heated up enough so repeat the ignition procedure after waiting 1 minute for gas to disperse. If problems