Switch Value Output of TFmini Plus v1.0
A10,Keshi Building, No.28, Xinxi Rd, Haidian district, Beijing, China. 100084 Page6
output level is high; and when the threshold100, the output level is low.)
the command is:
5A 09 3B 01 5E 01 05 00 00
threshold is 400cm, hysteresis range is 10cm (When the threshold100, the
output level is low; and when the threshold100, the output level is high.)
the command is:
5A 09 3B 02 90 01 0A 00 00
3. Enable data outputTurn on the output enable of the TFmini-Plus to start measuring
after the switch value mode is set up. The command is: 5A 05 07 01 00.
4. Restore factory settings (if necessary)command5A 04 10 00