EasyManua.ls Logo

Ashley DVAG11-DF - User Manual

Ashley DVAG11-DF
47 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
© 2023 United States Stove Company, 227 Industrial Park Rd., South Pittsburg, TN 37380 Ph. 800-750-2723
Owners Instruction and Operation Manual
* All Pictures In This Manual Are For Illustrative Purposes Only. Actual Product May Vary.
THIS MANUAL IS SUBJECT TO CHANGE WITHOUT NOTICE.
Save These Instructions In A Safe Place For Future Reference.
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon
monoxide, which is known to the State of California to cause
cancer, birth defects, and/or other reproductive harm. For
more information, go to www.P65warnings.ca.gov
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Please read this manual BEFORE
installing and operating this unit.
- Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other
appliance.
- WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
- Installation and service must be performed by a qualied installer, service agency or the gas supplier.


* Installation and service must be performed by a qualied installer, service agency or the gas supplier *
854081-4203M
R
DVAG11-DF, DVAG17-DF,
DVAG25-DF
Model Number:
Certied to ANSI STD Z21.86-2016 (R2021)
and Certied to CSA STD 2.32-2016 (R2021)
Report Number:

Questions and Answers

  • G
    gina84Aug 17, 2025
    What to do if Ashley DVAG11-DF Gas Detectors pilot lights but flame goes out when control knob is released?
    • A
      Andrea OwensAug 18, 2025
      If the pilot light goes out after you release the control knob on your Ashley Gas Detectors, ensure the control knob is fully pressed in and held for at least 30 seconds after the pilot lights. Also, check that the manual shutoff valve is fully open. A loose thermocouple connection at the control valve can also cause this; hand-tighten it until snug, then tighten a quarter turn more. Low gas pressure or a dirty pilot can also be the cause. Contact your local gas company to check gas pressure and clean the pilot or replace the pilot assembly if needed. If the thermocouple is damaged or the control valve is damaged, replace them.
  • R
    Ricky ThompsonAug 20, 2025
    What to do if Ashley DVAG11-DF Gas Detectors burner backfiring during combustion?
    • A
      Ana SchroederAug 20, 2025
      If the burner is backfiring during combustion in your Ashley Gas Detectors, the burner orifice may be clogged or damaged. Try cleaning the burner orifice, and if that doesn't work, replace it. It's also possible that the gas regulator is defective, in which case you should replace it.
  • B
    Brandi SloanAug 22, 2025
    What to do if Ashley DVAG11-DF burner does not light after pilot is lit?
    • R
      Robert AguirreAug 22, 2025
      If the burner on your Ashley Gas Detectors fails to light after the pilot is lit, the burner orifice might be clogged. Clean the burner orifice or replace it. Also, the burner orifice diameter could be too small, requiring you to replace the burner orifice. Low inlet gas pressure may also be the issue.
  • M
    Marilyn StricklandAug 26, 2025
    What to do if Ashley DVAG11-DF has gas odor even when control knob is in OFF position?
    • A
      Anthony RamseyAug 26, 2025
      If you smell gas from your Ashley Gas Detectors even when the control knob is in the OFF position, there may be a gas leak. Locate and correct all leaks. Alternatively, the control valve could be defective, requiring replacement.
  • M
    Matthew RobinsonAug 27, 2025
    Why Ashley Gas Detectors heater shuts off in use?
    • J
      josephfitzgeraldAug 28, 2025
      If your Ashley Gas Detectors heater shuts off while in use, it may be due to low line pressure. Also, the pilot might be partially clogged, so try cleaning the pilot.
  • J
    James BerryAug 30, 2025
    What to do if Ashley DVAG11-DF has yellow flame during burner combustion?
    • J
      Joseph HillAug 30, 2025
      If you notice a yellow flame during burner combustion in your Ashley Gas Detectors, the inlet pipe might be blocked; remove the blockage. Also, incorrect pipe connections could be the cause; connect the pipes according to the installation instructions. The gas regulator could also be defective, so consider replacing it.
  • A
    Andrea MullinsSep 1, 2025
    How to fix no spark at pilot when ignitor button is pressed in Ashley DVAG11-DF Gas Detectors?
    • S
      Susan SilvaSep 1, 2025
      If there's no spark at the pilot when you press the ignitor button on your Ashley Gas Detectors, several things could be wrong. The ignitor electrode might be broken, so replace it. It could also be that the ignitor electrode is not connected to the ignitor cable, so reconnect it. Check if the ignitor cable is pinched or wet; free it if pinched and keep it dry. If the ignitor cable is broken, replace it. Lastly, the piezo ignitor might be bad, so replace it.
  • Q
    qfischerSep 4, 2025
    What to do if Ashley DVAG11-DF Gas Detectors heater produces a whistling noise when burner is lit?
    • P
      pollardjeffreySep 4, 2025
      If your Ashley Gas Detectors heater makes a whistling noise when the burner is lit, try turning the control knob to the LO position and let it warm up for a minute, especially if the burner is cold. Air in the gas line can also cause this, so operate the burner until the air is removed from the line. Also, a dirty or partially clogged burner orifice can be the reason. Clean the burner orifice or replace it.
  • D
    Danielle MullinsSep 6, 2025
    Why Ashley DVAG11-DF Gas Detectors has delayed ignition of burner?
    • A
      Andrea BarrettSep 6, 2025
      If your Ashley Gas Detectors experiences delayed ignition of the burner, the burner or pilot orifice may be clogged. Clean or replace the burner or pilot orifice.
  • B
    Bridget BrownSep 9, 2025
    What to do if Ashley DVAG11-DF Gas Detectors ignitor button is pressed, there is spark at pilot but no ignition?
    • S
      Sean KirkSep 9, 2025
      If you're getting a spark at the pilot but no ignition on your Ashley Gas Detectors when you press the ignitor button, first check that the gas supply is turned on and the manual shutoff valve is open. Make sure the control knob is in the PILOT position and pressed in. If there's air in the gas lines from a recent installation, continue holding down the control knob and repeat the igniting operation until the air is removed. The pilot might also be clogged, so clean the pilot orifice or replace the pilot assembly. If the gas regulator setting is incorrect, replace the gas regulator.