EasyManua.ls Logo

Ashley DVAG17 - User Manual

Ashley DVAG17
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Do not store or use gasoline or other ammable vapors and liquids in the vicinity of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.
If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency or the gas supplier.
Installation and service must be performed by a qualied installer, service agency or the gas supplier.
This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes.
This appliance is only for use with the type of gas indicated on the rating plate. This appliance is not convertible
for use with other gases, unless a certied kit is used.
853277C-4103i
Warning: If the information in this manual is not followed exactly, a re or explosion may result causing property
damage, personal injury or loss of life.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
MODELS: DVAG11 / DVAG17 / DVAG30
CALIFORNIA PROPOSITION 65 WARNING:
This product can expose you to chemicals including carbon monoxide, which
is known to the State of California to cause cancer, birth defects and/or other
reproductive harm. For more information, go to www.P65warnings.ca.gov
Ce produit peut vous exposer à des agents chimiques, y compris au monoxyde de
carbone, lesquels sont reconnus dans l’État de la Californie comme causant le cancer et
des malformations congénitales ou autres dommages au fœtus. Pour obtenir plus de
renseignements, veuillez consulter le site www.P65warnings.ca.gov
United States Stove Company
PO Box 151, 227
Industrial Park Rd.,
South Pittsburg, TN 37380
PH: (800) 750-2723
www.usstove.com

Questions and Answers

  • S
    stephanie60Aug 18, 2025
    What to do if Ashley DVAG17 Gas Detectors pilot lights but flame goes out when control knob is released?
    • J
      Joanne SheltonAug 18, 2025
      If the pilot light goes out after you release the control knob on your Ashley Gas Detectors, ensure the control knob is fully pressed in and held for at least 30 seconds after the pilot lights. Also, check that the manual shutoff valve is fully open. A loose thermocouple connection at the control valve can also cause this; hand-tighten it until snug, then tighten a quarter turn more. Low gas pressure or a dirty pilot can also be the cause. Contact your local gas company to check gas pressure and clean the pilot or replace the pilot assembly if needed. If the thermocouple is damaged or the control valve is damaged, replace them.
  • T
    tracywilkersonAug 20, 2025
    What to do if Ashley Gas Detectors burner backfiring during combustion?
    • M
      mmoralesAug 20, 2025
      If the burner is backfiring during combustion in your Ashley Gas Detectors, the burner orifice may be clogged or damaged. Try cleaning the burner orifice, and if that doesn't work, replace it. It's also possible that the gas regulator is defective, in which case you should replace it.
  • C
    Colleen ChaseAug 23, 2025
    What to do if Ashley DVAG17 burner does not light after pilot is lit?
    • R
      Richard BrooksAug 23, 2025
      If the burner on your Ashley Gas Detectors fails to light after the pilot is lit, the burner orifice might be clogged. Clean the burner orifice or replace it. Also, the burner orifice diameter could be too small, requiring you to replace the burner orifice. Low inlet gas pressure may also be the issue.
  • T
    Tracy StoutAug 26, 2025
    What to do if Ashley Gas Detectors has gas odor even when control knob is in OFF position?
    • S
      shortdavidAug 26, 2025
      If you smell gas from your Ashley Gas Detectors even when the control knob is in the OFF position, there may be a gas leak. Locate and correct all leaks. Alternatively, the control valve could be defective, requiring replacement.
  • L
    Laurie TateAug 27, 2025
    Why Ashley Gas Detectors heater shuts off in use?
    • A
      Angela WoodsAug 28, 2025
      If your Ashley Gas Detectors heater shuts off while in use, it may be due to low line pressure. Also, the pilot might be partially clogged, so try cleaning the pilot.
  • N
    nrussellAug 30, 2025
    What to do if Ashley Gas Detectors has yellow flame during burner combustion?
    • S
      Samuel MillerAug 30, 2025
      If you notice a yellow flame during burner combustion in your Ashley Gas Detectors, the inlet pipe might be blocked; remove the blockage. Also, incorrect pipe connections could be the cause; connect the pipes according to the installation instructions. The gas regulator could also be defective, so consider replacing it.
  • T
    Timothy JoyceSep 1, 2025
    How to fix no spark at pilot when ignitor button is pressed in Ashley DVAG17?
    • S
      Shelby JamesSep 2, 2025
      If there's no spark at the pilot when you press the ignitor button on your Ashley Gas Detectors, several things could be wrong. The ignitor electrode might be broken, so replace it. It could also be that the ignitor electrode is not connected to the ignitor cable, so reconnect it. Check if the ignitor cable is pinched or wet; free it if pinched and keep it dry. If the ignitor cable is broken, replace it. Lastly, the piezo ignitor might be bad, so replace it.
  • B
    bruce39Sep 4, 2025
    What to do if Ashley DVAG17 heater produces a whistling noise when burner is lit?
    • P
      Patricia Richardson MDSep 5, 2025
      If your Ashley Gas Detectors heater makes a whistling noise when the burner is lit, try turning the control knob to the LO position and let it warm up for a minute, especially if the burner is cold. Air in the gas line can also cause this, so operate the burner until the air is removed from the line. Also, a dirty or partially clogged burner orifice can be the reason. Clean the burner orifice or replace it.
  • C
    Carla BrownSep 7, 2025
    Why Ashley DVAG17 has delayed ignition of burner?
    • J
      Jon BrewerSep 7, 2025
      If your Ashley Gas Detectors experiences delayed ignition of the burner, the burner or pilot orifice may be clogged. Clean or replace the burner or pilot orifice.
  • J
    Justin VargasSep 9, 2025
    What to do if Ashley DVAG17 Gas Detectors ignitor button is pressed, there is spark at pilot but no ignition?
    • J
      Jennifer WaltersSep 9, 2025
      If you're getting a spark at the pilot but no ignition on your Ashley Gas Detectors when you press the ignitor button, first check that the gas supply is turned on and the manual shutoff valve is open. Make sure the control knob is in the PILOT position and pressed in. If there's air in the gas lines from a recent installation, continue holding down the control knob and repeat the igniting operation until the air is removed. The pilot might also be clogged, so clean the pilot orifice or replace the pilot assembly. If the gas regulator setting is incorrect, replace the gas regulator.

Summary

What to Do If You Smell Gas

Massachusetts Installation Requirements

Carbon Monoxide Detector Installation

Mandated installation of CO detectors for safety.

Key Safety Warnings

Product Features

Appliance Installation Overview

Vent Terminal Clearances

Appliance Installation

Mounting Bracket on Non-Combustible Wall

Steps for mounting on masonry or concrete walls.

Mounting Bracket on Drywall;Wooden Wall

Steps for mounting on drywall or wooden walls.

Mounting Heater on Bracket

Venting System Installation

Gas Piping and Connections

Appliance Operation

Lighting Instructions

Step-by-step guide for lighting the pilot and main burner.

Turning Off the Appliance

Proper procedure for shutting down the appliance.

Post-Servicing Operation Check

Troubleshooting Guide

Service and Maintenance

Ashley DVAG17 Specifications

General IconGeneral
BrandAshley
ModelDVAG17
CategoryGas Detectors
LanguageEnglish

Related product manuals