DRAINAGE CONNECTION
The machine is supplied with a drainage hose attached,
which must be connected to a drain. See the examples
below. The height must be 600–900 mm above fl oor level.
The lower position (600 mm) is always preferable. Ensure
that the drainage hose has no kinks.
600--900 mm
The machine can also be connected to the drain via a
spigot connection. In this case the hose should also be
600-900 mm above the fl oor. The internal diameter of the
hole should be at least 18 mm.
• Cut the nipple
• Remove burrs from the hole. See the illustration.
At least 18 mm
ELECTRICAL INSTALLATION
If the machine is delivered from the factory with a plug
attached it can be connected to an earthed wall socket.
Otherwise, a permanent connection using a multipolar
circuit breaker must be made by a qualifi ed professional.
CAUTION!
If this appliance is supplied from a cord extensions
set or electrical portable outlet device, the cord
extension ser or electrical portable outlet device must
be positioned so that it is not subject to splashing or
ingress of moisture.
Connection on delivery
The machine comes with 1-Phase, 230 V, 50 Hz, heat
output 3000 W and fused 16 A. If a residual current
device is being used, this should be type A.
NOTE!
Repairs and maintenance must be carried out by a
qualifi ed professional.
INSTALLATION