TD 73
Filter clogged
The overheating cutout (150°C) will operate, and the machine stops.Must be reset
manually.
Moisture sensor not installed in the fan casing or fault in the control unit
The machine stops after ca 20 min.
Incoming suppIy fuses blown
Fuse L1 blown: Machine will stop after ca. 20 minutes. Heater power will be reduced
(720W)
Fuse L2 blown:The machine will not start. Main power On light extinguished.
Fuse L3 blown: Machine operates, but with extended running time (low heater power
1900W).
380V between phase and neutral
The fan motor will stop after a few seconds. The overheating cutout will operate, but
the heater and controls will be destroyed.