Page 5
Memory capacity: The sensor stores a total of 950 events. Earlier events are overwritten in
the circular buffer, but the first and the 8 peak shock values including details are
permanently stored. This ensures that you can document the highest shock forces on your
transported goods in detail.
Calculation table as orientation aid for the setting of activity events (Interval recording):
Tips for using profiles
If your transport is only on the road for a few days and you want to record the position of
the goods and also the climate data constantly, select a shorter interval for activity events,
for example every 2 hours. For longer transports of several weeks, select a longer interval,
for example, every 8 hours.
Example: Profile for recording climate data for 30 days, interval-based
To ensure that you receive few shock events, define the following settings: battery life 600
days, shock 12 g, shock duration 40 ms, activity event for orientation and climate = 2 hours,
deactivate temperature and relative humidity thresholds. You will receive a value for
temperature and humidity every two hours for a period of 30 days.
Please note: You can make further global settings such as the extended display of shocks up
to ± 24 g per axis, the control of the app, and other, in the Global settings area.