7
CANVARO STS INSTRUCTION SHEET
Control and motor system: Oelschläger Metalltechnik GmbH
Adjustment mechanism: Spindle adjustment in the leg
Synchronization: electr. synch. by electr. control unit
Tube diameter of the lift columns: 70 mm / 65 mm / 60 mm (outside / middle / inside)
Temperature range at point of use: + 5°C to + 40°C
Max. relative humidity: 80 %
Rated voltage: 230 V ~
Rated frequency: 50 Hz
Intermittent periodic duty: max. 2 min / 18 min
Maximum load: Desk: 100 kg
CPU holder: 15 kg
Equipment holder: 15 kg
Protection class: IP 20
Maximum power consumption
during lifting operation: 2 lift columns 450 W
Power consumption in
standby mode: < 0.3 W
Traversing speed: 50 mm/s (without load)
Maximum adjustment range: 650 mm
Control panel up / down: Standard
Operating panel with
memory function: Optional (wired)
Noise emission: < 45 dB(A)
Rating plates are located on the control system housing,
the lift columns and underneath the desktop.