Das ASSMANN Prinzip. Gute Arbeit. www.assmann.de
Benutzerinformation Canvaro STS
Technical data Canvaro.
12
Controlbox CDB4 and CBD6, lift column DL11 –Canvaro
Control and motor system: LINAK
Adjustment mechanism: Spindle adjustment in the leg
Synchronization: Electric synchronization by the electrical control unit
Tube diameter of the lift columns: 70 mm / 63.5 mm / 57 mm (outside / middle / inside)
Temperature range at point of use: + 5 °C to + 40 °C
Max. relative humidity: 80%
Rated voltage: 230 V AC ~ ± 10%
Rated frequency: 50 Hz
Intermittent periodic duty: max. 2 min / 18 min
Maximum load: Desk 75 kg
CPU holder 20 kg
Equipment holder 20 kg
Type of protection: IP 40
Maximum power consumption during lifting operation:: 2 lift columns 400 W (CDB4)
3 lift columns 600 W (CDB6)
Power consumption in standby mode: 0,1 W
Traversing speed: 38 mm/s (without load)
Maximum adjustment range: 600 mm
Control panel up / down: Standard
Bedienpaneel Memory: Optional (verkabelt)
Noise level: max. 48 dB(A)
Rating plates are located on the control system housing, the lift columns and underneath the desktop.