Figure 4. Schematic diagram for system connections
Mount AD511 active antenna with clear view of sky using bracket
supplied.
Attach top end of coax down-lead to N type connector on underside
of antenna.
Attach bottom end of down-lead to N type connector to the Power
Break-In Box AD510-40 . The down-lead must not be shortened by the
user.
Attach interconnect between TNC on AD510-40 and telephone (or
base station) using the antenna adapter provided with the phone.
Attach DC supply lead to +18 to +36 v DC supply (600mA max). Red
lead to +supply, Blue to –supply.
Turn on Iridium telephone and log-in.