- Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use
any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a neigh-
bor’s phone. Follow the gas supplier’s instruc-
tions.
If you cannot reach your gas supplier, call the
fire department.
- Installation and service must be performed by
a qualified installer, service agency or the gas
supplier.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
AVERTISSEMENT:
RISQUED’INDENDIE OU D’EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d’entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d’essence ni d’autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L’installation et l’entretien doivent être assurés par
un installateur ou un service d’entretien qualifié
ou par le fournisseur de gaz.
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
Installateur : Laissez cette notice avec l’appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or
mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated
on the rating plate. This appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d’autres gaz, sauf si une trousse de conversion est utilsée.
Installation and Operation Instructions
Models
CUS
Report No. F13-094
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900684-04.
P/N 900684-00 REV. A 03/2017
Gemini™ Direct-Vent Gas Fireplaces
Gemini33TMN-B
Gemini33TMP-B
Gemini33TEN-B
Gemini33TEP-B
Gemini33RMN-B
Gemini33RMP-B
Gemini33REN-B
Gemini33REP-B
Gemini35DMN-B
Gemini35DMP-B
Gemini35DEN-B
Gemini35DEP-B
Gemini40DMN-B
Gemini40DMP-B
Gemini40DEN-B
Gemini40DEP-B
Gemini45DMN-B
Gemini45DMP-B
Gemini45DEN-B
Gemini45DEP-B
P900684-00

Table of Contents

Questions and Answers

  • D
    Debra KingAug 14, 2025
    What to do if the main burner does not light on my Astria Fireplaces Gemini33TMN-B Indoor Fireplace, even though the igniter is sparking?
    • K
      Kevin MunozAug 14, 2025
      If the main burner of your Astria Fireplaces Indoor Fireplace doesn't light while the igniter is sparking, check the gas supply and shutoff valves to ensure gas is reaching the unit. Inspect the control compartment for loose wires connected to the valve or ignition module. If there is air in the gas line, purge it. Also, replace the unit's battery backup. If necessary, call a service technician.
  • D
    Danielle BaileyAug 18, 2025
    What should I do if my Astria Fireplaces Gemini33TMN-B is not turning ON or OFF?
    • M
      Maria KimAug 18, 2025
      If your Astria Fireplaces Indoor Fireplace isn't responding to the ON/OFF switch, make sure the wall switch plate is set to REMOTE. Check the gas supply and gas shutoff valves to ensure gas is reaching the fireplace. Also, check or replace the backup batteries behind the wall plate.
  • A
    apetersonAug 21, 2025
    Why does my Astria Fireplaces Gemini33TMN-B pilot light not stay lit?
    • J
      Jennifer ArmstrongAug 21, 2025
      If the pilot light on your Astria Fireplaces Indoor Fireplace won't stay lit, ensure the pilot flame is correctly impinging on the thermocouple. Clean and adjust the pilot for maximum flame impingement on the thermocouple. Also, make sure the connection between the valve and thermocouple is tight and secure.
  • K
    kellytravisAug 25, 2025
    What to do if my Astria Fireplaces Gemini33TMN-B Indoor Fireplace main burner comes on and then goes out?
    • M
      melissa70Aug 25, 2025
      If the main burner of your Astria Fireplaces Indoor Fireplace comes on but then goes out, check the gas supply and gas shutoff valves. Inspect the control compartment for any loose wires connected to the valve or ignition module. If these steps don't solve the issue, it may be necessary to call a service technician to check the pilot flame and vent system.
  • C
    Cynthia DavidsonAug 28, 2025
    How to troubleshoot frequent pilot/burner outage on my Astria Fireplaces Indoor Fireplace?
    • M
      Michelle WillisAug 28, 2025
      If you're experiencing frequent pilot/burner outages with your Astria Fireplaces Indoor Fireplace, the pilot flame might be too low or too high, causing the valve safety to drop out. Clean and adjust the pilot flame for maximum flame impingement on the thermocouple.
  • J
    jesse56Aug 31, 2025
    How to fix a spark igniter that won't light the pilot on my Astria Fireplaces Gemini33TMN-B?
    • K
      kristy93Aug 31, 2025
      If the spark igniter on your Astria Fireplaces Indoor Fireplace doesn't light the pilot, check for a spark at the electrode and pilot. If there's no spark and the electrode wire is properly connected, replace the igniter. If there is a spark, light the pilot with a match. If it lights, the gas mixture may be improper, needing a longer purge. If it still won't light, check the gap at the electrode and pilot, ensuring it's 1/8". If the gap is correct, replace the pilot. Also, check the inlet gas pressure to ensure it's within the limits marked on the rating plate. Finally, clean or replace the pilot orifice if it's plugged.
  • M
    Mark DixonSep 3, 2025
    Why is there soot on the logs and glass of my Astria Fireplaces Indoor Fireplace?
    • W
      William CampbellSep 4, 2025
      Soot on the logs and glass of your Astria Fireplaces Indoor Fireplace can be due to several reasons. Ensure the logs are properly positioned. A white film may develop during initial operation, so clean the glass after each use until it stops. Also, adjust the air shutter opening according to the instructions.
  • R
    Rhonda McphersonSep 7, 2025
    What causes poor flame or blue flame in my Astria Fireplaces Gemini33TMN-B Indoor Fireplace?
    • B
      Brooke ThomasSep 7, 2025
      A poor or blue flame in your Astria Fireplaces Indoor Fireplace can be caused by a door seal that isn't properly aligned, leading to gaps and air leaks. Remove and realign the door to ensure the gasket seal is fully engaged around the door frame.

Astria Fireplaces Gemini33TMN-B Specifications

General IconGeneral
ModelGemini33TMN-B
CategoryIndoor Fireplace
Fuel TypeNatural Gas
Vent TypeDirect Vent
Ignition TypeElectronic Ignition
FinishBlack
Glass TypeTempered Glass
BTU25, 000 BTU
Dimensions33" Wide
Ignition SystemElectronic