NOTE:
@ The test unit of area is "V"
@ If the measurement range at the
maximum (500V setting) "HV" will
be displayed on the screen
Connect the test leads to the circuit under test (connect the
leads in parallel to the power supply or circuit under test) to
measure.
After the reading stabilizes, record the reading from the LCD
screen.
Turn the rotary switch to the OFF position to turn off the
Meter.
VOLTAGE TIPS:
HOW TO FIND A LIVE WIRE IN A SOCKET:
Switch to the voltage test setting
Connect the black test lead to the grounded wire or jack
Connect the red test lead to one of the jacks to be
measured
Check both jacks. One should have a reading and the other
should remain at or near zero. The live wire will have the
reading.
VOLTAGE NOTES:
Choose the 500V setting to measure the unknown voltage first,
and then select the appropriate range according to the voltage
-12