NOTE:
@ The test unit of area is "V"
@ If the measurement range at the
maximum (500V setting) "HV" will
be displayed on the screen
• Connect the test leads to the circuit under test (connect the
leads in parallel to the power supply or circuit under test) to
measure.
• After the reading stabilizes, record the reading from the LCD
screen.
• Turn the rotary switch to the OFF position to turn off the
Meter.
VOLTAGE TIPS:
HOW TO FIND A LIVE WIRE IN A SOCKET:
• Switch to the voltage test setting
• Connect the black test lead to the grounded wire or jack
Connect the red test lead to one of the jacks to be
measured
• Check both jacks. One should have a reading and the other
should remain at or near zero. The live wire will have the
reading.
VOLTAGE NOTES:
• Choose the 500V setting to measure the unknown voltage first,
and then select the appropriate range according to the voltage
-12